DIM.
MIN.
MAX.
鈩?/div>
ambient temperature unless otherwise specified.
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%
CHARACTERISTICS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward
Rectified Current
@TL =110 C
SYMBOL
V
RRM
V
RMS
V
DC
I
(AV)
FS3A
50
35
50
FS3B
100
70
100
FS3C
150
105
150
3.0
FS3D
200
140
200
FS3G
400
280
400
FS3J
600
420
600
UNIT
V
V
V
A
Peak Forward Surge Current
8.3ms single half sine-wave
super imposed on rated load (JEDEC METHOD)
Maximum forward Voltage at 3.0A DC
Maximum DC Reverse Current @TJ =25 C
at Rated DC Blocking Voltage @TJ=125 C
Maximum Reverse Recovery Time (Note 1)
Typical Reverse Recovery Time
Typical Junction Capacitance (Note 2)
Typical Thermal Resistance (Note 3)
Typical Thermal Resistance (Note 3)
Operating Temperature Range
Storage Temperature Range
I
FSM
V
F
I
R
T
RR
T
RR
C
J
R
胃
JL
R
胃
JA
T
J
T
STG
35
20
0.92
100
1.25
10
500
50
30
45
10
50
-55 to + 150
-55 to + 150
15
1.30
A
V
uA
ns
ns
pF
C/W
C/W
C
C
NOTES : 1. Reverse Recovery Test Conditions :I
F
=0.5A,I
R
=1.0A,I
RR
=0.25A.
2. Measured at 1.0MHz and applied reverse voltage of 4.0V DC.
3. Thermal Resistance junction to Lead.