Availability in flame-retardant material.
鈥?/div>
AST-FR has the following agency approvals:
鈥擜BS (American Bureau of Shipping)
鈥擠NV (Det Norske Veritas)
鈥擫loyd鈥檚 (Lloyd鈥檚 Register of Shipping)
Installation
Minimum shrink temperature: 90擄C
Minimum full recovery temperature: 121擄C
Speci鏗乧ations/Approvals
廬
廬
Series
SST
SST-FR
UL
CSA
Military
MIL-DTL-23053/15A*,
Class 1 and Class 2
Industry
AST-FR
AST
*Formerly MIL-I-23053/I5A.
ASTM D 685, nonburning
ASTM D 2863, oxygen index
IPCEA S-19-81, cable insulation and jackets
IEEE-383 Section 2.5 massive 鏗俛me vertical tray
ABS, DNV, Lloyd鈥檚 Register
RW 2017
RW 2011
Raychem
Nemosyne 90
Nemosyne FR
Product Dimensions
(inches)
Mil-Spec
approved
part number
鈥?/div>
SST*-03
SST*-04
SST*-07M
SST*-07
SST*-11M
SST*-11
SST*-13M
SST*-13
SST*-15M
SST*-15
SST*-17M
SST*-17
SST*-20M
SST*-20
SST*-27
SST*-30
SST*-40
SST*-45
鈥?/div>
In
Agency
approved
part number
AST 8/3
AST 10/4
AST 19/6(M)
AST 19/6
AST 33/10(M)
AST 33/10
AST 43/13(M)
AST 43/13
AST 51/19(M)
AST 51/19
AST 69/23
AST 76/32
AST 114/45
Standard
nominal
length
6
6
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
12, 18, 24
12, 18, 24
12, 18, 24
12, 18, 24
Internal diameter
Minimum
Maximum
expanded recovered
0.300
.100
0.400
.150
0.750
.220
0.750
.220
1.100
.375
1.100
.375
1.300
.375
1.300
.375
1.500
.500
1.500
.500
1.700
.500
1.700
.500
2.000
.750
2.000
.750
2.700
.900
3.000
1.250
4.000
1.750
4.500
1.750
Wall thickness (nominal)
Expanded
.025
.025
.020
.030
.030
.040
.025
.035
.035
.050
.030
.045
.040
.050
.050
.050
.050
.050
Recovered
鈥犫€?/div>
.060
.060
.060
.095
.105
.120
.105
.120
.120
.140
.120
.140
.120
.155
.155
.155
.155
.155
Recommended cable
range for 600-volt cable
#18 through #14 AWG
#14 through #10 AWG
#8 through #1 AWG
#8 through #1 AWG
#2 through #4/0 AWG
#2 through #4/0 AWG
#2 through #4/0 AWG
#2 through #4/0 AWG
#2/0 AWG through 500 MCM
#2/0 AWG through 500 MCM
#2/0 AWG through 500 MCM
#2/0 AWG through 500 MCM
#350 MCM through 1000 MCM
#350 MCM through 1000 MCM
#500 MCM through 1250 MCM
#900 MCM through 1500 MCM
#1500 MCM through 2500 MCM
#1500 MCM through 2500 MCM
place of asterisk* substitute length of tubing to be ordered. For example, SST*-11, as the third column indicates, comes in 6-, 9-, and 12-inch lengths, so 9-inch SST tubing would be
SST 9-11. The suf鏗亁 M = medium-wall tubing.
鈥犫€?/div>
Wall thickness will be less if tubing recovery is restricted during shrinkage.
3-42
Tubing
R
Users should independently evaluate the suitability of the product for their application.
next