5,000 V - 12,500 V Rectifier Stacks
0.5 A Forward Current
3000 ns Recovery Time
SP50S SP75S
SP100S SP125S
ELECTRICAL CHARACTERISTICS AND MAXIMUM RATINGS
Part Number
Working
Reverse
Voltage
(Vrwm)
Average
Rectified
Current
(in oil)
(Io)
55擄C
Volts
SP50S
SP75S
SP100S
SP125S
Amps
100擄C
Amps
Reverse
Current
@ Vrwm
(Ir)
25擄C
碌A(chǔ)
100擄C
碌A(chǔ)
25擄C
Volts
Amps
Forward Voltage
1 Cycle
Surge
Current
tp=8.3ms
(Ifsm)
25擄C
Amps
Repetitive
Surge
Current
(Ifrm)
25擄C
Amps
Reverse
Recovery
Time
(1)
(Trr)
25擄C
ns
in.
Case Length
(L)
(Vf)
5000
7500
10000
12500
0.5
0.5
0.5
0.5
0.33
0.33
0.33
0.33
1.0
1.0
1.0
1.0
25
25
25
25
8.5
17.0
17.0
25.5
2.0
2.0
2.0
2.0
40
40
40
40
8
8
8
8
3000
3000
3000
3000
1.125
1.625
2.000
2.375
8
(1)Trr Testing: If=0.5A, Ir=1.0A, Irr=0.25A *Op. Temp.= -55擄C to +150擄C Stg. Temp.= -55擄C to +150擄C
2.00(50.80)
MIN.
.500 鹵.020
(12.70 鹵.50)
L 鹵.020
0.51 鹵.003
(1.30 鹵.08)
.250 鹵.020
(6.35 鹵.50)
Dimensions: In. (mm) 鈥?All temperatures are ambient unless otherwise noted. 鈥?Data subject to change without notice.
VOLTAGE MULTIPLIERS INC.
8711 W. Roosevelt Ave.
Visalia, CA 93291
TEL
559-651-1402
FAX
559-651-0740
www.voltagemultipliers.com
187