S102S03/S202S03
S102S03/S202S03
s
Features
1. High radiation resin mold package
2. RMS ON-state current I
T
: MAX. 8 Arms
at T
C
<= 80藲C ( With heat sink )
3. Isolation voltage between input and output
( V
iso
: 4 000V
rms
)
4. Low input driving current
( I
FT
: MAX. 5mA )
5. Approved by CSA, No. LR63705
Recognized by UL, file No. E94758
SIP Type SSR with Mounting
Capability for External Heat
Sink
s
Outline Dimensions
( Unit : mm )
* The metal parts marked *
are common to terminal 1 .
g
Do not allow external connection.
( )
:
Typical dimensions
18.5
鹵
0.2
16.4
鹵
0.3
蠁
3.2
鹵
0.2
*
A ( Model No. )
B
S102S03
8A125VAC
S202S03
8A250VAC
3.2
鹵
0.2
5.5
鹵
0.2
5.0
鹵
0.3
s
Applications
1. Automatic vending machines
2. Programmable controllers
3. Amusement equipment
鹵
0.2
g
0.2
MAX.
A
B
+ -
4.2
MAX.
1
2
3
4
s
Model Line-ups
For 100V lines
S102S03
For 200V lines
S202S03
(5.08) (7.62)
(2.54)
0.6
鹵
0.1
(1.4)
Internal connection diagram
1
2
3
4
1
2
3 4
Output ( Triac T2 )
Output ( Triac T1 )
Input (
+
)
Input (
-
)
s
Absolute Maximum Ratings
Parameter
Input
Forward current
Reverse voltage
RMS ON-state current
*1
Peak one cycle surge current
Repetitive peak OFF-state voltage
Non-repetitive peak OFF-state voltage
Critical rate of rise of ON-state current
Operating frequency
*2
Isolation voltage
Operating temperature
Storage temperature
*3
Soldering temperature
Symbol
I
F
V
R
I
T
I
surge
V
DRM
V
DSM
dI
T
/d
t
f
V
iso
T
opr
T
stg
T
sol
(Ta = 25 藲C )
Rating
S102S03 S202S03
50
6
*4
8
80
400
600
400
600
50
45 to 65
4 000
- 25 to + 100
- 30 to + 125
260
Unit
mA
V
A
rms
A
V
V
A/
碌s
Hz
V
rms
藲C
藲C
藲C
*1 50Hz sine wave,
Tj = 25藲C start
*2 60Hz AC for 1 minute,
40 to 60% RH, Apply
voltages between input
and output by the
dielectric withstand
voltage tester with
zero-cross circuit.
( Input and output shall
be shorted respectively ) .
( Note )
When the isolation voltage is
necessary at using external
heat sink, please use the
insulation sheet.
*3 For 10 seconds
*4 T
C
<= 80藲C
Output
鈥?/div>
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.鈥?/div>
11.2
MIN.
4
-
1.1
4
-
1.25
鹵
0.3
4
-
0.8
鹵
0.2
19.6
鹵
0.2
(36.0)
next