1.0 GENERAL
RCPW (Remote Configuration Package for Windows) runs on a PC and
communicates via an interface adaptor to enable re-programming and
interrogation of the transmitter.
3.2 Connection using Configuration Module
When configuration is made using an existing loop, the loop power supply
must be capable of supplying 30mA and the load resistor chosen so that
at least 10v remains across the transmitter, taking into account all other
volt drops within the loop.
There are two possible methods of connecting the PC to the transmitter
as below.
(A) Configurator Powered Programming
4.0 PROGRAMMING
4.1 Menu Structures
RCPW contains the following menus: File, View, Options, Devices and
Help. These options can be selected with the mouse or by simultaneously
depressing <ALT> and the letter underlined as above. Once a menu
option has been selected, the status bar shows a brief description of the
functions which are as follows:
2.0 UNPACKING
Please check carefully for any signs of shipping damage. The packaging
has been designed to afford maximum protection, however, we cannot
guarantee that mishandling will not cause damage. In the case of this
unlikely event, please contact your supplier immediately for a Returns
number and we will send a form to be completed and returned with the
instrument. Please retain the packaging for subsequent inspection.
鈥?/div>
Check that the power supply is the correct voltage for your country.
1
2
3
4
Black
Lead
Red
Lead
5
Power
Supply
Ribbon Cable
Connected to
PC serial port
3.0 CONFIGURATION
A programming kit package is available containing all the accessories to
facilitate programming the transmitter straight away. The full contents are
as follows:
鈥?/div>
The configurator for connection between the PC and the mA-
signal of the transmitter
鈥?/div>
Power supply unit with output 24 V DC, 150 mA for connection to
mains
鈥?/div>
RCPW Installation disk
鈥?/div>
Instructions (this document)
鈥?/div>
Transmitter to configurator connection cable
LED
6
7
8
9
10
LED
Power
Supply
RIBBON CABLE
Connected to
PC serial port
(B) Configuration for In-Loop Programming
Loop
power
supply
24V
Minimum
Loop Load
250
鈩?/div>
R
Minimum
Loop Load
250
鈩?/div>
Field wiring
FUNCTION
File
New
Open
Close
Save
Save As
Print
Print Preview
Print Setup
Exit
View
Toolbar
Status Bar
Options
Set Password
Enable Password
Set Comm port
Enable Config. Verification
Set Network Mode
Devices
Scan Devices
Configure
Read
Modify Device Address
Monitor
Help
Help
About
DESCRIPTION
Create a new device template
Open an existing template
Close template
Save template
Save template as...
Print the active document
Preview the active document
Setup options for printing
Exit RCPW
1
2
3
+ 24V
- SYSTEM
3.1 PC Installation of RCPW
Minimum PC operating system: Windows鈩?3.1
Minimum PC requirement:
IBM廬 compatible 386 or above with 4mb
RAM and available serial port
Insert the "RCPW" disk into your PC and run A:\Setup.
Installation directory for the storage defaults to C:\RCPW which can be
amended. Icons are automatically created to run RCPW and to uninstall.
4
Black
Lead
Red
Lead
5
Ribbon Cable
Connected to
PC serial port
LED
6
7
8
9
10
LED
Programming Socket
Show or hide the toolbar
Show or hide the status bar
RIBBON CABLE
Connected to
PC serial port
3.3 Connection with direct cable (Optional extra)
Power
Supply
Set or change the password
Enable or disable the password
Choose serial comms port
Enable verification of parameters
Set network to single or multi device
ACC200/06 Cable
Scan for devices on the network
Configure device with template parameter
Read device parameter into template
Modify the address of a device
Monitor devices
Detailed help
Program information, version, copyright
52-214-2244-01