General Purpose Relays
SCHRACK
Power PCB Relay PCFN Solar
I
I
I
I
I
1 pole, 26 A, 1 NO Contact
contact gap > 1.5 mm
200 mW hold power
Ambient temperature up to 75擄C, 85擄C at 22 A
RoHS compliant (Directive 2002/95/EC)
Applications: Photovoltaic inverter
F-PCFNsolar
Approvals
V
data of approved types on request
U
Technical
Contact data
Contact configuration
Contact set
Contact gap
Rated current
Rated voltage
Maximum breaking capacity AC
Contact material
Mechanical endurance
Rated frequency of operation with / without load
1 N/O
single contact
> 1.5 mm
26 A
277 VAC
7200 VA
AgSnO
2
1x10
6
cycles
6 / 300 min
-1
Contact ratings
Load
22 A, 250 VAC, resistive, 85擄C
26 A, 250 VAC, resistive, 75擄C
Cycles
30x10
3
30x10
3
Coil data
Rated coil voltage
Coil power
Coil insulation system according UL 1446
12 VDC
1.5 W
1)
class F
Coil version, DC-coil
Coil
Rated
Operate
Release
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
Ohm
W
12
12
7.8
1.2
96+10%
1.5
All figures are given for coil without preenergization, at ambient temperature +23擄C
Hold voltage
W
4.4 V at ambient temperature
w
85擄C
1)
Ambient temperature > 23擄C requires reduction of coil voltage to 4.4...< 6 V after
100ms
1
Datasheet
Rev. HC1
Issued 2008/03
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
鈥楽chrack鈥?section.
Specifications subject to
change.