The NTE1919 is a 3 terminal fixed negative voltage regulator in a TO3 type package designed for use
in applications requiring a well regulated positive output voltage. Outstanding features include full power
usage up to 1.5A of load current, internal current limiting, thermal shutdown, and safe area protection
on the chip, providing protection of the series pass Darlington, under most operating conditions.
Hermetically sealed steel packages are utilized for high reliability and low thermal resistance. A low鈥?/div>
noise temperature stable band鈥揼ap reference is the key design factor insuring excellent temperature
regulation of the NTE1919. This coupled to a very low output impedance insures superior load regula-
tion.
Features:
D
Guaranteed Input鈥揙utput Differential: V
IN
鈥?V
O
= 鈥?.1V
D
Low Noise, Band Gap Reference
D
Remote Sense Capability
D
Sample Power Cycled Burn鈥揑n
D
Guaranteed Thermal Resistance Junction鈥搕o鈥揅ase: R
thJC
= 3擄C/W
Absolute Maximum Ratings:
Input Voltage (Note 1), V
IN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 鈥?0V
Power Dissipation, P
D
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internally Limited
Derate Above T
C
= 105擄C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333mW/擄C
Operating Junction Temperature Range, T
J
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 鈥?5擄 to +150擄C
Storage Temperature Range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 鈥?5擄 to +150擄C
Lead Temperature (During Soldering, 60sec Max), T
L
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +300擄C
Thermal Resistance, Junction鈥搕o鈥揅ase, R
thJC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3擄C/W
Note 1. Short circuit protection is only assured to V
IN
max. In case of short circuit, with input鈥搊utput
voltages approaching V