音影先锋亚洲天堂网|电影世界尽头的爱完整版播放|国产 熟女 91|高清无码免费观看欧美日韩|韩国一区二区三区黄色录像|美女亚洲加勒比在线|亚洲综合网 开心五月|7x成人在线入口|成人网站免费日韩毛片区|国产黄片?一级?二级?三级

NLN Datasheet

  • NLN

  • NLN/NLS Class K5 Fuses

  • 2頁

  • LITTELFUSE   LITTELFUSE

掃碼查看芯片數(shù)據(jù)手冊

上傳產(chǎn)品規(guī)格書

PDF預覽

NLN/NLS Class K5 Fuses
250/600 VAC
I
鈥淥NE-TIME鈥?/div>
I
1 鈥?600 Amperes
SPECIFICATIONS
Voltage Ratings:
AC: 250 Volts (NLN, NLKP)
600 Volts (NLS)
DC: 250 Volts (NLN)
400 Volts (NLS 35 鈥?60A)
500 Volts (NLS 8 鈥?15A)
(NLS 225 鈥?600A)
600 Volts (NLS 1 鈥?7A)
(NLS 20 鈥?30A)
(NLS 70 鈥?200A)
Interrupting Ratings:
AC: 50,000 amperes rms symmetrical (NLN/NLS)
10,000 amperes (NLKP)
DC: 20,000 amperes (NLN/NLS 1 鈥?60A)
50,000 amperes (NLN/NLS 70 鈥?600A)
Ampere Range:
1鈥?600 amperes (NLN/NLS)
15 鈥?60 amperes (NLKP)
Approvals:
NLN/NLS: Standard 248-9, Class K5
UL Listed (File No: E81895)
CSA Certified (File No: LR29862)**
**Excludes NLN 15-60A
NLKP: Standard 248-6, Class H
UL Listed (File No: E81895)
CSA Certified (File No: LR29865)
Meets CSA 鈥淭ype P鈥?requirements
AMPERE RATINGS
1
7
* 25
* 60
125
300
2
8
* 30
70
150
350
3
10
* 35
80
175
400
4
12
* 40
90
200
450
5
* 15
* 45
100
225
500
6
* 20
* 50
110
250
600
* NLKP series available only in those amperages preceded
by an asterisk.
Example part number (series & amperage): NLS 125
NLN and NLS series fuses provide low cost protection for
general purpose feeder and branch circuits when available
short circuit currents are less than 50,000 amperes. They
replace all Class H fuses which have only a 10,000 ampere
interrupting rating. They are suitable for use in many resi-
dential and smaller commercial and industrial applications.
NLKP series fuses are Canadian 鈥淐ode鈥?fuses specifically
designed to meet Canadian Electrical Code Type P fuse
requirements for residential use. They have a 10,000
ampere interrupting rating.
However, to obtain the added benefits of time-delay, current-
limitation, and higher interrupting rating, consider the use of
POWR-PRO
IDSR Indicator
TM
fuses for circuits between
250 and 600 volts. The user gets all the benefits of time-delay
RK5 fuses plus the added benefits of an indicating fuse that
tells when it has opened. Complete information on these
fuses may be found in the POWR-PRO
section of this
catalog. For circuits up to 250 volts, see FLNR fuses in this
section of the catalog.
RECOMMENDED FUSE BLOCKS
LH250 series (for NLN and NLKP series fuses)
LH600 series (for NLS series fuses)
Refer to Fuse Block section of this catalog for additional
information.
APPLICATIONS
General purpose residential and commercial circuits with
little or no motor load.
Resistive heating loads.
ECONOMICAL
I
NOTE:
NLKP series fuses have limited interrupting rating and
should be used only where available short circuit current is
known to be less than the fuse interrupting rating. Where
available fault current is unknown, where it exceeds NLN/NLS
interrupting rating, or where it may increase in the future,
200,000 ampere interrupting rating Littelfuse POWR-PRO
TM
FLNR_ID/FLSR_ID Indicator
TM
fuses and FLNR/FLSR series
fuses provide superior protection for all motor and general
purpose circuits containing inductive loads.
For use in applications where lowest initial cost is the
major consideration.
SAFETY
I
50,000 A.I.R., Class K5 鈥?Adequate interrupting capacity
for residences and many smaller facilities.
34

NLN相關(guān)型號PDF文件下載

您可能感興趣的PDF文件資料

掃碼下載APP,
一鍵連接廣大的電子世界。

在線人工客服

買家服務(wù):
賣家服務(wù):
技術(shù)客服:

0571-85317607

網(wǎng)站技術(shù)支持

13606545031

客服在線時間周一至周五
9:00-17:30

關(guān)注官方微信號,
第一時間獲取資訊。

建議反饋

聯(lián)系人:

聯(lián)系方式:

按住滑塊,拖拽到最右邊
>>
感謝您向阿庫提出的寶貴意見,您的參與是維庫提升服務(wù)的動力!意見一經(jīng)采納,將有感恩紅包奉上哦!