NET1 SERIES
Designed to meet the stringent requirements of today鈥檚 high-speed
datacom and telecom circuitry, Power-One鈥檚 NET1 series is an excellent
compact power solution for low-voltage, high-current applications. The
NET1鈥檚 high efficiency is achieved through the use of synchronous
rectification and a newly-patented 鈥淪oft Transition Forward Converter鈥?
The NET1鈥檚 rectification method lowers output losses, reduces system
cooling requirements (allowing greater power in a smaller package), and
eliminates minimum load requirements.
Advanced Produc
t
Release
Advanced surface-mount design and packing technology reduce the
NET1鈥檚 height to 1.35鈥?(34.3mm) to fit in 1U applications. NET1鈥檚
high-performance active power factor circuitry meets EN61000-3-2
requirements for compliance with European Power Line Harmonic
Requirements for 2001. A multifunctional output terminal allows
connection to #8 ring lugs, 0.25鈥?quick disconnects, cable connectors,
and PCB-mounted connectors.
FEATURES
鈥?Currents Over 100 Amps
鈥?Fits 1U Chassis Height Constraints
鈥?No Minimum Load Requirement
鈥?Current Share Capabilities on All Outputs
鈥?Patented High-Efficiency Design
鈥?Meets European Power Factor Requirements for 2001
鈥?Excellent Load Transient Response
MULTIPLE OUTPUT MODEL SELECTION CHART 鈥?/div>
240W WITH 300 LFM FORCED AIR COOLING
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%Pk-Pk (NOTE 2)
INITIAL SETTING
ACCURACY
NET1-4325
NET1-4130
NET1-4112
+3.3V
+2.5V
+5V
+12V
+1.8V
+3.3V
+5V
+12V
+1.8V
+1.65V
+5V
+12V
+0.5V
+0.5V
FIXED
FIXED
+0.5V
+0.5V
FIXED
FIXED
+0.5V
+0.5V
FIXED
FIXED
50A
50A
5A
4A
50A
50A
5A
4A
50A
50A
5A
4A
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
1%
1%
3%
3%
1%
1%
3%
3%
1%
1%
3%
3%
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
鹵 30mV
鹵 30mV
鹵 30mV
鹵 100mV
鹵 20mV
鹵 30mV
鹵 30mV
鹵 100mV
鹵 20mV
鹵 30mV
鹵 30mV
鹵 100mV
NOTES:
1) Output currents ratings are expressed with 300 LFM forced air.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
TYP
MAX
UNITS
Input Voltage - AC
Input Frequency
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor
Continuous input range.
AC input.
After last AC line peak at 240 watts.
85 VAC at full rated load.
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 220 VAC, one cycle, 25擄C.
Per EN61000-3-2.
85
47
20
4.0
264
63
VAC
Hz
mS
A
RMS
A
PK
W/VA
35
0.95
Rev. 11/2000
1
next