鈥?/div>
MC9S08QG8
MC9S08QG4
MCU Device Mask Set Identification
The mask set is identified by a 5-character code consisting of a version number, a letter, two numerical
digits, and a letter, for example 3M77B. All standard devices are marked with a mask set number and a
date code.
Possible High Current in Stop Mode If KBI/IRQ Enabled
Description
SE96B-IRQ_KBI
In stop mode, with the IRQ or KBI pin functions enabled but the IRQ/KBI interrupt disabled, a toggle on the
IRQ/KBI pin will turn on the voltage regulator and oscillator, causing the clocks to run. This results in
higher stop I
DD
. In this condition, the CPU is halted (as if in wait mode) and the chip level interrupt is not
generated. This higher current condition can also happen if the flag is set at time of stop entry.
漏 Freescale Semiconductor, Inc., 2006, 2007. All rights reserved.