鈥?/div>
Relays
Ordering Information
A complete part number is represented by the digits to the right. For example, MN2S1030 is a
MINI-DYAD鈩?with a minimum operate value of 10 and a maximum of 30. Refer to the switch
operating specification charts for available ranges. Special ranges are available upon request.
MN2S
Minimum Operate Value (NI)
XX XX
X
XX
Packaging
Maximum Operate Value (NI)
Lead Configuration
Surface Mount Mini-Dyad
Refer to operating characteristics table for complete part number.
Approvals
鈥?/div>
UL listed
Mini-DYAD
TM
Part #
MN2S1015
MN2S1020
MN2S1030
MN2S1520
MN2S1525
MN2S2025
Operate Range (NI)
1
10 to 15
10 to 20
10 to 30
15 to 20
15 to 25
20 to 25
Standard Test Coil
The magnetic force (expressed in NI, AT or Ampere Turns) required to cause the reed switch contacts to
close is called the pull-in or operate value.
MN2
Part #
Coil definition
Coil resistance
Number of turns
Wire size (nom. diameter)
Bobbin diameter (inside coil)
Winding length
Coil - 1
NARM1 CTC01
1200鈩?/div>
5,000
0.0399mm (AWG 46)
3.96mm
10.4mm
Mini-DYAD
TM
Surface Mount
Part #
MN2308
MN2288
MN2339
MN2285
MN2289
MN2286
1
2
Operate Range (NI)
1,2,3
10 to 15
10 to 20
10 to 30
15 to 20
15 to 25
20 to 25
(1)
Consult factory for test procedure.
The reed switch shall be placed in the test coil with the gap centered in the core of the coil winding.
Test leads and their clips must be non-magnetic.
The longitudinal axis of the test coil and the test switch shall be vertical.
Tolerance =
鹵
1.5NI
Full Blade Sensitivity
3
Surface Mount Switches are packaged 2,000 parts per reel
DS-MN2-R2
www.clare.com
1
next