Tyco/Electronics
Raychem Circuit Protection
308 Constitution Drive
Menlo Park, CA 94025-1164
800-227-4856
FAX 800-227-4866
PolySwitch廬
PTC Devices
Overcurrent Protection Device
PRODUCT: LVR012S
DOCUMENT: SCD 24904
PCN: D63011
REV LETTER: I
REV DATE: JUNE 18, 2003
PAGE NO.: 1 OF 2
Specification Status:
RELEASED
Electrical Rating at 20擄C
Rated Operating Voltage: 240 V
AC
Rated Interrupt Current: 1.2 A
RMS
Max Interrupt Voltage: 265 V
AC
Insulating Material :
Cured, Flame Retardant Epoxy Polymer
Meets UL94 V-0 Requirements.
Lead Material:
24 AWG Sn Plated Copper
Marking:
240
L012
Raychem Logo
and Voltage
Part Identification
Lot Identification
(can be on back)
TABLE I. DIMENSIONS:
A
mm:
in*:
B
MIN
4.3
(0.17)
C
MAX
5.8
(0.23)
MIN
7.6
(0.30)
D
MAX
--
--
MIN
--
--
E
MAX
3.8
(0.15)
MIN
MAX
MIN
MAX
--
8.3
--
10.7
--
(0.33)
--
(0.43)
*Rounded off approximation
TABLE II. PERFORMANCE RATINGS:
I
HOLD
RATED
CURRENT
AMPS AT
20
o
C
HOLD
0.12
CURRENT RATINGS
TIME TO TRIP
RESISTANCE
POST-TRIP
RESISTANCE
STANDARD
TRIP
OHMS
AT 20
o
C
MAX
12.0
NOMINAL
TRIPPED
POWER
DISSIPATION
WATTS
AT 20
o
C
1.0
AMPS
AT 20
o
C
HOLD
0.12
TRIP
0.30
SECONDS AT
20
o
C, 0.6A
MAX
15.0
OHMS
AT 20
o
C
MIN
MAX
3.0
6.5
Recognitions:
Reference Documents:
Precedence:
Effectivity:
Warning:
UL, TUV, CSA recognized.
PS300
This specification takes precedence over documents referenced herein.
Reference documents shall be the issue in effect on the date of invitation for bid.
Refer to Page 2 of this document for application limitations.