鈥?Line Regulation 0.015% / V Typical.
鈥?Load Regulation 0.1% Typical.
鈮?/div>
2.16 (0.085)
11
7.62 (0.300)
7.12 (0.280)
17
18
1
2
0.76 (0.030)
0.51 (0.020)
10
9
8
BLOCK DIAGRAM
V
IN
7
6
5
4
3
1.65 (0.065)
1.40 (0.055)
0.33 (0.013)
Rad.
0.08 (0.003)
1.39 (0.055)
1.15 (0.045)
0.43 (0.017)
0.18 (0.007 Rad.
THERMAL
LIMIT
LCC4
Pads 5,4 = adjust
Pads 6,7,8,9,10,11,13 = Vin
Pads 1,2,15,16,17,18 = Vout
V
ADJ
V
OUT
ABSOLUTE MAXIMUM RATINGS
V
I-O
P
D
V
IN
T
J
T
STG
Input鈥揙utput Differential Voltage
Power Dissipation
Operating Input Voltage
Operating Junction Temperature Range
Storage Temperature Range
Thermal Resistance (junction to case)
(T
case
= 25擄C unless otherwise stated)
30V
Internally limited
25V
Control
Power
鈥?5 to 150擄C
鈥?5 to 200擄C
鈥?5 to 150擄C
13擄C/W
q
JC
* Although the devices鈥?maximum operating voltage is limited to 25V the devices are guaranteed to withstand transient
input voltages up to 30V. For input voltages greater than the maximum operating input voltage, some degradation of
specifications will occur.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail:
sales@semelab.co.uk
Website:
http://www.semelab.co.uk
Prelim. 8/00