鈥?/div>
Universal input
3鈥?x 5鈥?footprint
Remote sense on main output
Built-in EMI filter
Low output ripple
Adjustable main output
Overvoltage protection
Overload protection
110 KHz switching frequency
LPX60 enclosure kit available
Safety ground
leakage current
Output
Maximum power
60 W for convection (LPT61, 35 W);
80 W with 30 CFM forced air (LPT61,
55 W)
-5, +10% minimum
鹵2% on output 1;
鹵5% on outputs 2,3
20 ms @ 60 W load, 115 VAC nominal
line
Short circuit protection on all
outputs. Case overload protected @
110-145%
above peak rating
5.7-6.7 VDC on main output
LPT61: 3.6 to 4.6 VDC
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
Adjustment range
Cross regulation
Hold-up time
Overload protection
Environmental
Overvoltage protection
Operating temperature: 0擄 to 50擄C ambient
derate each output at 2.5% per degree from
50擄 to 70擄C
Electromagnetic susceptibility: designed to meet
IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.75G peak 5 Hz to 500 Hz, operational
Storage temperature: -40擄 to 85擄C
Temperature coefficient: 鹵.04% per 擄C
MTBF demonstrated: >550,000 hours at full load
and 25擄C ambient conditions
VDE
UL
CSA
NEMKO
BABT
CB
CE
Remote sense
Safety
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 Level 3
EN 60950/EMKO-TUE
(74-sec) 203
EN60950/BS7002
Certificate and report
Mark (LVD)
11774-3336-1255 (LC #86665)
E132002
LR53982C
P95100123
PS / 605273
1518, 1519, 1520
96
America鈥檚 (USA): 1-888-41-ASTEC
Europe (UK): 44 (1384) 842-211
Asia (HK): 852-2437-9662