鈥?/div>
Totally enclosed
Universal input
Quick Installation
Built-in EMI filter
Low output ripple
Overvoltage protection
Overload protection
Safety ground leakage
current
Output
Maximum power
Cross regulation
Hold-up time
Overload protection
47 W with 12 CFM forced air
鹵2% on output 1;
鹵5% on outputs 2, 3
10 ms @ 47 W load, 100 VAC input
Short circuit protection on all
outputs.
Case overload protected @ 110-
135% above peak rating
5.50-6.75 VDC on main output
Environmental
Operating temperature: 0擄 to 50擄C ambient;
derate each output at 2.5% per degree from
50擄 to 70擄C
Electromagnetic susceptibility: designed to meet
IEC 1000-4, -2, -3, -4, -5, -6, 8, 11 Level 3
Humidity: Operating; non-condensing
5% to 90%
Vibration: .41 G from 3 to 500 Hz
Spectral break points of .0065 G2/Hz at 10 Hz and
200 Hz and 5 db/octave roll off at each end, 2
hours per axis
Storage temperature: -40擄 to 85擄C
Temperature coefficient: 鹵.04% per 擄C
MTBF demonstrated: >300,000 hrs @ full load and
25擄C ambient conditions
VDE
UL
CSA
CB
CE
Overvoltage protection
Safety
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 -950-95-M90
Certificate and report
Mark (LVD)
21310-3336-0003
E186249
6593
rev 8.11.04
90
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662