L9651
SMART QUAD SWITCH
s
s
s
s
s
s
s
Modified VDMOS Power Stage (U
DSBR
> 80V)
RDSON < 500 mOhm (T
j
= 25擄C)
CMOS Compatible Inputs
Enable Input (Reset)
Outputs Capable of up to 2.2 Amperes
Outputs Internally Clamped at 70V for Fast
Inductive Load Switch Off
Wide operating supply voltage from 4.7V up to
30V
PowerSO-20
ORDERING NUMBER: L9651
DIAGNOSTIC FUNCTIONS
s
Open Load Detection (Output off, 100碌s-
filtering time)
s
Short to Ground Detection (Output off, 100碌s -
filtering time)
s
Short to Battery Detection (Output on)
s
s
s
s
Serial Interface Clock Frequency up to 500kHz
Over temperature detection (Output on)
Storage of last fault in 8 Bit - Serial Register
Fault Signal Indication at Serial Data Out
without need to read out the Serial Interface
Daisy Chainable Serial Diagnostic
DESCRIPTION
The L9651 consists of four identical low side power
switches. A serial diagnostic interface indicates fail-
ure mode of each switch (short circuit to V
BAT
or
ground and open load or over temperature).
s
BLOCK DIAGRAM
V
BAT
Turn On
q
Data In
Clock
Sync.
Underv. Shutd.
Serial Data Out
q
q
q
Reset
References
Serial Diagnostic
Fault Detection
q
Inputs 1..4
Logic
Gate
Control
Four Fold
q
Short Circuit
Protection
Ground
April 2001
Output 1..4
1/9