HS-1840ARH-T
Data Sheet
July 1999
File Number
4589.1
Radiation Hardened 16 Channel CMOS
Analog Multiplexer with High-Z Analog
Input Protection
Intersil鈥檚 Satellite Applications Flow
TM
(SAF) devices are fully
tested and guaranteed to 100kRAD Total Dose. These QML
Class T devices are processed to a standard 鏗俹w intended
to meet the cost and shorter lead-time needs of large
volume satellite manufacturers, while maintaining a high
level of reliability.
The HS-1840ARH-T is a Radiation Hardened, monolithic 16
channel multiplexer constructed with the Intersil Rad-Hard
Silicon Gate, Dielectric Isolation process. It is designed to
provide a high input impedance to the analog source if
device power fails (open), or the analog signal voltage
inadvertently exceeds the supply by up to
鹵35V,
regardless
of whether the device is powered on or off. Selection of one
of sixteen channels is controlled by a 4-bit binary address
plus an Enable-Inhibit input, which conveniently controls the
ON/OFF operation of several multiplexers in a system. All
inputs have electrostatic discharge protection.
Features
鈥?QML Class T, Per MIL-PRF-38535
鈥?Radiation Performance
- Gamma Dose (緯) 1 x 10
5
RAD(Si)
- No Latch-Up, Dielectrically Isolated Device Islands
鈥?Improved r
DS(ON)
Linearity
鈥?Improved Access Time 1.5碌s (Max) Over Temp and Rad
鈥?High Analog Input Impedance 500M鈩?During Power Loss
(Open)
鈥?/div>
鹵35V
Input Over Voltage Protection (Power On or Off)
鈥?Excellent in Hi-Rel Redundant Systems
鈥?Break-Before-Make Switching
Pinouts
HS1-1840ARH-T (SBDIP), CDIP2-T28
TOP VIEW
+V
S
1
NC 2
NC 3
IN 16 4
IN 15 5
IN 14 6
IN 13 7
IN 12 8
IN 11 9
IN 10 10
IN 9 11
GND 12
(+5V
S
) V
REF
13
ADDR A3 14
28 OUT
27 -V
S
26 IN 8
25 IN 7
24 IN 6
23 IN 5
22 IN 4
21 IN 3
20 IN 2
19 IN 1
18 ENABLE
17 ADDR A0
16 ADDR A1
15 ADDR A2
Speci鏗乧ations
Speci鏗乧ations for Rad Hard QML devices are controlled by
the Defense Supply Center in Columbus (DSCC). The SMD
numbers listed below must be used when ordering.
Detailed Electrical Speci鏗乧ations for the HS-1840ARH-T
are contained in SMD 5962-95630.
A 鈥渉ot-link鈥?is provided
from our website for downloading.
www.intersil.com/spacedefense/newsafclasst.asp
Intersil鈥檚 Quality Management Plan (QM Plan), listing all
Class T screening operations, is also available on our
website.
www.intersil.com/quality/manuals.asp
Ordering Information
ORDERING
NUMBER
5962R9563002TXC
HS1-1840ARH/Proto
5962R9563002TYC
HS9-1840ARH/Proto
PART
NUMBER
HS1-1840ARH-T
HS1-1840ARH/Proto
HS9-1840ARH-T
HS9-1840ARH/Proto
TEMP.
RANGE
(
o
C)
-55 to 125
-55 to 125
-55 to 125
-55 to 125
HS9-1840ARH-T (FLATPACK) CDFP3-F28
TOP VIEW
+V
S
NC
NC
IN 16
IN 15
IN 14
IN 13
IN 12
IN 11
IN 10
IN 9
GND
(+5V
S
) V
REF
ADDR A3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
28
27
26
25
24
23
22
21
20
19
18
17
16
15
OUT
-V
S
IN 8
IN 7
IN 6
IN 5
IN 4
IN 3
IN 2
IN 1
ENABLE
ADDR A0
ADDR A1
ADDR A2
NOTE:
Minimum order quantity for -T is 150 units through
distribution, or 450 units direct.
1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
www.intersil.com or 407-727-9207
|
Copyright
漏
Intersil Corporation 1999
Satellite Applications Flow鈩?(SAF) is a trademark of Intersil Corporation.
next