VDE
2c, 3c
10 AMP POWER RELAY
HP-RELAYS
25
.984
36
1.417
FEATURES
鈥?Interchangeable with existing models
鈥?Long life and high reliability
鈥?High contact capacity up to 10 A 250 V AC
鈥?Available with plug-in/solder and quick-connect terminals
44.5
1.752
mm
inch
SPECIFICATIONS (at 20
擄
C
68
擄
F)
Contacts
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Rating
Remarks
* Speci鏗乧ations will vary with foreign standards certi鏗乧ation ratings.
*
1
Measurement at same location as "initial breakdown voltage" section
*
2
Detection current; 10 mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10
碌
s
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10
碌
s
*
7
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Characteristics (at 60 Hz, 20
擄
C
68
擄
F)
2 Form C 3 Form C 4 Form C
15 m
鈩?/div>
Silver
Silver
alloy
Maximum operating speed
Initial insulation resistance*
1
Between open
contacts
Breakdown
voltage*
2
Between contact sets
Between contact and
coil
Operate time*
3
(at nominal voltage)
Release time (without diode)*
3
(at nominal voltage)
Temperature rise
Shock resistance
Functional*
Destructive*
5
4
2 Form C 3 Form C 4 Form C
20 cpm
more than 100 M
鈩?/div>
at 500 V DC
1,000
2,000
1,000
Vrms
Vrms
Vrms
1,500
Vrms
1,500
Vrms
Approx.
15 ms
Approx.
15 ms
2,000
Vrms
2,000
Vrms
1,500
Vrms
1,500
Vrms
Nominal switching
capacity
10 A 250 V AC (resistive)
Approx. 25 ms
Approx. 25 ms
Max. 65
擄
C
98 m/s
2
{10 G}
980 m/s
2
{100 G}
58.8 m/s
2
{6 G}, 10 to 55 Hz
at 1 mm double amplitude
117.6 m/s
2
{12 G}, 10 to 55 Hz
at 2 mm double amplitude
鈥?0
擄
C to +40
擄
C
鈥?8
擄
F to +104
擄
F
5 to 85% R.H.
Approx.
60g
2.12 oz
Approx.
100g
3.53 oz
Approx.
125g
4.41 oz
Functional*
6
Vibration resistance
Destructive
Conditions for opera- Ambient
tion, transport and
temp.
storage*
7
(Not freezing and
condensing at low
Humidity
temperature)
Unit weight
LIFE DATA
Contact rating and expected life For AC load type
Voltage
Load
Electrical
life
125 V AC
Resistive (cos
蠒
]
1) Inductive (cos
蠒
]
0.4)
鈥?/div>
鈥?/div>
10 A
5A
1A
7.5 A
3A
0.7 A
Mechanical life
250 V AC
Resistive (cos
蠒
]
1) Inductive (cos
蠒
]
0.4)
10 A
7.5 A
7.5 A
3A
0.6 A
5A
2A
0.4 A
Expected life
(min. operations)
2
脳
10
5
5
脳
10
5
1
脳
10
6
2
脳
10
6
1
脳
10
7
Current
Note: When the electromagnet or exciting coil (Solenoid, etc.) is the load, the value of motor or lamp load is applicable.
411
next