designed for operation in the 17.7-19.7GHz frequency range.
This amplifier has an input and output designed for use in 50鈩?/div>
systems.This device is well suited for point-to-point communication
applications.
Eudyna鈥檚 stringent Quality Assurance Program assures the highest
reliability and consistent performance.
ABSOLUTE MAXIMUM RATINGS (Ambient Temperature Ta=25擄C)
Parameter
DC Input Voltage
DC Input Voltage
Input Power
Storage Temperature
Operating Case Temperature
Symbol
VDD
VGG
Pin
Tstg
Top
Condition
Rating
10
-7
22
-55 to +125
-40 to +85
Unit
V
V
dBm
擄C
擄C
Eudyna recommends the following conditions for the long term reliable operation of GaAs FETs:
1. The drain-source operating voltage (VDD) should not exceed 6 volts.
ELECTRICAL CHARACTERISTICS (Ambient Temperature Ta=25擄C)
Item
Frequency Range
Output Power at 1 dB G.C.P.
Power Gain at 1 dB G.C.P.
Gain Flatness
Drain Current at 1 dB G.C.P.
Gate Current at 1 dB G.C.P.
Power-Added Efficiency at 1dB G.C.P.
Input Return Loss
Output Return Loss
Symbol
f
P
1dB
G
1dB
鈭咷
Iddrf
Iggrf
畏
add
RLin
RLout
VDD = 6V
VGG = -5V
f= 17.7-19.7GHz
ZS = ZL = 50鈩?/div>
29
18
-
-
-
-
-
-
Conditions
Limits
Min. Typ. Max.
17.7 - 19.7
31
20
1.0
800
-12
27
-10
-6
-
25
-
950
-15
-
-
-
Unit
GHz
dBm
dB
dB
mA
mA
%
dB
dB
G.C.P.: Gain Compression Point