鈥?/div>
Increased System Power
Density
MAXIMUM RATINGS
Symbol
V
R
V
RRM
V
RWM
I
F
(AV)
I
F
(RMS)
I
FSM
T
J
,T
STG
T
L
Characteristic / Test Conditions
Maximum D.C. Reverse Voltage
Maximum Peak Repetitive Reverse Voltage
Maximum Working Peak Reverse Voltage
All Ratings Are Per Leg: T
C
= 25擄C unless otherwise specified.
APT30D60BCT
UNIT
600
Volts
Maximum Average Forward Current (T
C
= 100擄C, Duty Cycle = 0.5)
RMS Forward Current
Non-Repetitive Forward Surge Current (T
J
= 45擄C, 8.3ms)
Operating and StorageTemperature Range
Lead Temperature: 0.063" from Case for 10 Sec.
30
70
320
-55 to 150
300
擄C
Amps
STATIC ELECTRICAL CHARACTERISTICS
Symbol
Characteristic / Test Conditions
I
F
= 30A
V
F
Maximum Forward Voltage
I
F
= 60A
I
F
= 30A, T
J
= 150擄C
I
RM
C
T
L
S
Maximum Reverse Leakage Current
V
R
= V
R
Rated
V
R
= V
R
Rated, T
J
= 125擄C
Junction Capacitance, V
R
= 200V
Series Inductance (Lead to Lead 5mm from Base)
APT Website - http://www.advancedpower.com
Bend, Oregon 97702-1035
F-33700 Merignac - France
Phone: (541) 382-8028
Phone: (33) 5 57 92 15 15
FAX: (541) 388-0364
FAX: (33) 5 56 47 97 61
MIN
TYP
MAX
UNIT
1.8
1.5
1.6
250
500
40
10
碌A(chǔ)
pF
nH
053-6016 Rev -
Volts
USA
405 S.W. Columbia Street
EUROPE
Avenue J.F. Kennedy B芒t B4 Parc Cad茅ra Nord