42 Volt nominal rating / 58 Volt interrupting rating
Unique keying design prevents lower rated fuses from being
inserted into the circuit
Same performance characteristics as industry standard JCASE
fuse but modified to work in the 42 volt environment
ELECTRICAL CHARACTERISTICS:
% of
Opening
(Rating)
Time
110%
100 hrs.,
Minimum
135%
60 sec.,
Min.;
1800 sec.,
Max.
200%
4.00 sec.,
Min.;
60.0 sec.,
Max.
350%
0.20 sec.,
Min.;
17.0 sec.,
Max.
600%
0.04 sec.,
Min.;
1.0 sec.,
Max.
5.50
(.22")
14.10
(.56")
12.00
(.47")
+
+
+
6.75 (.27")
1.00
(.039")
Interrupting Rating:
1000A @ 58 VDC
Voltage Rating:
58 VDC
Ambient Temp:
-40
o
C to +125
o
C
ORDERING INFORMATION:
Typical Voltage Nominal Cold
Ampere
Rating Voltage Rating Body Drop at Rated Resistance
Catalog
(鈩?
(A)
(VDC)
Color Current (mV)
Number
995
020
995
025
995
030
995
040
995
050
995
060
20
25
30
40
50
60
58
58
58
58
58
58
Blue
Natural
Pink
Green
Red
Yellow
125
120
115
115
115
115
.00486
.00328
.00245
.00152
.00118
.00095
27.0
(1.06")
18.7
(.74")
0.38
(.015")
10.10
(.40")
12.10
(.48")
4.40
(.17")
10.00
(.39")
24.4
(.96")
10.00
(.39")
45擄
Avera ge Time Current Cur ves
20A
30A
40A
50A
60A
1000
100
12
10
1
0.1
0.01
1
10
100
1000
CURRENT IN AMPERES
10000
w w w. l i t t e l f u s e . c o m
457
BLADE TERMINAL AND
SPECIAL PURPOSE FUSES
TIME IN SECONDS