鈥?/div>
Grid current modulator
Power Supply Feedback
Switching between power supplies
Patient station isolation
DESCRIPTION
In the
66005,
high voltage isolation is provided with a GaAlAs light emitting diode and by your choice of outputs, either
silicon phototransistor or photodarlington, hermetically sealed in TO-46 packages and mounted in a high reliability,
hermetically sealed, ceramic package. Available in commercial (0
擄
to +70
擄
C), extended temperature range (-40
擄
to +85
擄
C)
and full Military temperature range (-55
擄
to +125
擄
C).
Contact the factory for special custom or multi-channel
requirements!
ABSOLUTE MAXIMUM RATINGS
Collector-Emitter Voltage (Value applies to emitter-base open-circuited & the input-diode equal to zero) ...................... 35V
Emitter-Collector Voltage...................................................................................................................................................... 7V
Continuous Collector Current .......................................................................................................................................... 50mA
Continuous Transistor Power Dissipation ..................................................................(see Note 1) ............................. 250mW
Input to Output Isolation Voltage .......................................................................................................................................16kV
Input Diode Continuous Forward Current at (or below) 65
擄
C Free-Air Temperature .................................................. 100mA
Reverse Input Voltage ......................................................................................................................................................... 2V
Continuous LED Power Dissipation ..........................................................................(see Note 1) .............................. 250mW
Storage Temperature...................................................................................................................................... -65
擄
C to +150
擄
C
Operating Free-Air Temperature Range ........................................................................................................ -55
擄
C to +125
擄
C
Lead Solder Temperature (1/16鈥?from case for 10 seconds max.).................................................................................240
擄
C
Notes:
1. Derate linearly to 125
擄
C free-air temperature at the rate of 2.45 mW/
擄
C.
Package Dimensions
Schematic Diagram
C
E
K
A
-X02
B
C
ANODE(+)
COLLECTOR (+)
脴0.0175 [脴0.44]
BASE
脴0.0175 [脴0.44]
CATHODE(-)
EMITTER(-)
16,000 V, BLACK DOT
RED DOT
2 LEADS
3 LEADS
脴0.1550 [脴3.94]
(1)
A
-X01
(3)
(5)
(4)
(3)
脴0.3100 [脴7.87]
(2)
(1)
0.500 MIN [12.70]
0.500 MIN [12.70]
0.8493 [21.57]
(2)
K
B
(5)
(4)
ALL DIMENSIONS ARE IN INCHES [MILLIMETERS] NOMINAL
NOTE: BLACK DOT INDICATES ANODE FOR LED
RED DOT INDICATES COLLECTOR FOR
TRANSISTOR.
MICROPAC INDUSTRIES, INC. OPTOELECTRONIC PRODUCTS DIVISION
鈥?/div>
725 E. Walnut St., Garland, TX 75040
鈥?/div>
(972) 272-3571
鈥?/div>
Fax (972) 487-6918
www.micropac.com
E-MAIL: optosales@micropac.com
7-5