Sicherungsstreifen
f眉r Flurf枚rderzeuge f眉r Nennspannungen bis 80 V /
Fuse strips
for batterie-powered vehicles for rated voltage up to 80 V /
Fusibles-lames
pour v茅hicules 脿 batterie pour tension nom. jusqu'脿 80 V
Metallteile / Metal parts / Pi貓ces m茅talliques:
35 A - 80 A:
Zn-Legierung / Zinc-alloy / Zinc-alliage
100A - 425 A:
Kupfer Cu, gal. Sn / Copper Cu, gal. Sn / Cuivre Cu, gal. Sn
Verpackungseinheit / Packaging unit / Emballage:
50 St眉ck / pieces / pi貓ces
Artikel-Nr.
Article-No.
R茅f. d'article
Nennstrom
Rated current
Intensit茅 nom.
a = 11 mm
157.5700.5351
157.5700.5401*
157.5700.5501
157.5700.5631
157.5700.5801
157.5700.6101
157.5700.6121
157.5700.6131*
157.5700.6141*
157.5700.6151*
157.5700.6161
157.5700.6171*
157.5700.6201
157.5700.6231*
157.5700.6251
157.5700.6271*
157.5700.6301
157.5700.6331*
157.5700.6351
157.5700.6401*
157.5700.6421
157.5700.6501*
a = 9 mm*
157.5916.5351*
157.5916.5501*
157.5916.5631*
157.5916.5801*
157.5916.6101*
157.5916.6121*
157.5916.6131 *
157.5916.6141*
157.5916.6151*
157.5916.6161*
157.5916.6171*
157.5916.6201*
157.5916.6251*
I
N
/I
rat
Spannungsfall
Voltage drop
Chute de tension
U
D
PUDENZ
max.
35 A
40 A
50 A
63 A
80 A
100 A
125 A
130 A
135 A
150 A
160 A
175 A
200 A
225 A
250 A
275 A
300 A
325 A
355 A
400 A
425 A
500 A
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
* in der Normreihe nicht verzeichnet / not mentioned in the standards / pas mentionn茅 dans la norme
zugeh枚riger Halter siehe Seite 52-53 / corresponding holder see page 52-53 / porte-fusible correspondant voir page 52-53
Schmelzzeit-Grenzwerte
/
Pre-arcing time - limits
/
Temps de fusion limits
min.
max.
-
-
Ma脽e in mm / Dimensions in mm / Dimensions en mm
1,50 I
N
/ I
rat
35 A - 200 A
1h
225 A - 425 A 60 s (1,6In)
2,20 I
N
/ I
rat
35 A - 200 A
225 A - 425 A
-
-
60 s
60 s
2,50 I
N
/ I
rat
35 A - 200 A
225 A - 425 A
800ms
-
10 s
10 s
4,00 I
N
/ I
rat
35 A - 200 A
225 A - 425 A
250ms
250ms
2s
2s
Normen / Specifications / Normes
DIN
F
I
= 1,00 (max. Dauerstrom / max. operating current / max. courant permanent: 1,0 x I
rat
bei / at / 脿 23擄C)
43560/1
In our continuing strategy to deliver unparalleled circuit protection solutions,
technical expertise and application leadership,we proudly introduce the
WICKMANN Group and its products to the Littelfuse portfolio.
WebSite
www.littelfuse.com