10 Watt CD Single Series DC/DC Converters
Features
!
High Temperature Operation, up to 110擄C Case
with No Derating
Fully Self Contained, No External Parts Required
for Operation, Ultra Low Input Reflected Ripple
Fixed Frequency Design
Low and Specified Input/Output Capacitance
Overcurrent Protected for Long, Reliable Operation
Five-sided Shielding
Water Washable Case Design
Five Year Warranty
!
!
!
!
!
!
!
Description
The 24S5.2000CD DC/DC converter is designed for fast
integration with your system鈥檚 power needs. With no external
components or filtering necessary for all but the most critical
applications, these converters can provide power instantly.
This saves you costly engineering time required to design
your system around the power converter.
Model
Selection Chart
Input Range
VDC
Min
Max
18
36
Output
VDC
5
Output
mA
2000
24S5.2000CD
Output Parameters*
Input Parameters*
Model
Voltage Range
Reflected Ripple (2)
Input Current Full Load
No Load
Efficiency
Switching Frequency
Maximum Input
Overvoltage,
100ms Maximum
Turn-on Time,
1% Output Error
Recommended Fuse
MIN
MAX
TYP
TYP
TYP
TYP
TYP
MAX
TYP
24S5.2000CD
18
36
20
495
7
84
220
45
6
(3)
Units
VDC
mA P-P
mA
%
kHz
VDC
ms
AMPS
Model
Output Voltage
Output Voltage Accuracy
Rated Load Range
Load Regulation
25% Max Load -
Max Load
Line Regulation
Vin = Min-Max VDC
Short Term Stability (5)
Transient Response (6)
Dynamic Response (7)
Input Ripple Rejection (8)
Noise, Peak - Peak (2)
Temperature Coefficient
Short Circuit Protection to
Common
MIN
TYP
MAX
MIN
MAX
TYP
MAX
TYP
MAX
TYP
TYP
TYP
TYP
TYP
TYP
MAX
24S5.2000CD
5
4.90
5.00
5.10
0.0
2.0
0.2
0.4
0.03
0.2
< 0.05
250
90
> 40
70
50
150
Units
VDC
VDC
A
%
%
%/24Hrs
碌s
mV peak
dB
mV P-P
ppm/擄C
A
Continuous, Current Limit
Protection
NOTES
*
(2)
(3)
(4)
(5)
All parameters measured at Tc = 25擄C, nominal input voltage
and full rated load unless otherwise noted. Refer to the
CALEX Application Notes for the definition of terms,
measurement circuits and other information.
Noise is measured per CALEX Application Notes. Measurement
bandwidth is 0-20 MHz for peak-peak measurements, 10 kHz to
1 MHz for RMS measurements. Output noise is measured with
a 0.01碌F / 100V ceramic capacitor in parallel with a 1碌f / 35V
Tantalum capacitor across output pins. Input reflected ripple
is measured into a 10碌H source impedance.
To determine the correct fuse size, see CALEX Application
Notes.
The Case is tied to the -input pin.
Short term stability is specified after a 30 minute warmup at full
load, constant line and recording the drift over a 24 hour period.
The transient response is specified as the time required to settle
from a 50 to 75 % step load change (rise time of step = 2 碌Sec)
to a 1% error band.
(7) Dynamic response is the peak overshoot during a transient
as defined in note 6 above.
(8) The input ripple rejection is specified for DC to 120 Hz ripple with
a modulation amplitude of 1% of Vin.
(9) The case thermal impedance is specified as the case temperature
rise over ambient per package watt dissipated.
(10) Specifications subject to change without notice.
(6)
2401 Stanwell Drive 鈥?Concord, California 94520 鈥?Ph: 925/687-4411 or 800/542-3355 鈥?Fax: 925/687-3333 鈥?www.calex.com 鈥?Email: sales@calex.com
1