Blade Terminal & Special Purpose Fuses
Low Voltage
RoHS
Cable Pro
廬
Cable Protector
496 Series
Opening Time
100 hours,
Minimum
120 sec.,
Min.;
1800 sec.,
Max.
10 sec.,
Min.;
300sec.,
Max.
1 sec.,
Min.;
15 sec.,
Max.
0.3 sec.,
Min.;
5 sec.,
Max.
UL
廬
ELECTRICAL CHARACTERISTICS:
% of Ampere
Rating
100%
135%
200%
350%
600%
CABLE TYPE:
SAE J1127(4 & 6 AWG) & SAE J1128(8 AWG).
INTERRUPTING RATINGS:
2000 amperes @ 32 VDC
ENVIORNMENTAL SPECIFICATIONS:
Operating Temperature Range: -40藲C to +125藲C
Temperature Rerating Curve
Rerating Factor (% Rated Current)
110
105
100
95
90
85
-40
-20
0
20
40
60
80
100
120
Ambient Temperature (藲C)
80A
100A
125A
150A
175A
200A
10
100
1000
ORDERING INFORMATION:
Catalog Ampere
Number Rating
0496
080
80
0496
100 100
0496
125 125
0496
150 150
0496
175 175
0496
200 200
0496
060
60
Wire
Typical Voltage Drop
Size
at Rated Current (mV)*
8mm
2
(8AWG)
117.0
8mm
2
(8AWG)
119.9
13mm
2
(6AWG)
104.6
19mm
2
(4AWG)
102.1
19mm
2
(4AWG)
105.4
2
19mm (4AWG)
97.6
5mm
2
(10AWG)
132.8
Nominal Cold
Resistance (m鈩?*
1.188
0.937
0.697
0.555
0.473
0.374
1.770
1000
100
* NOMINAL COLD RESISTANCE AND TYPICAL VOLTAGE DROP AT RATED CURRENT IS
MEASURED AT THE ENDS OF TWO 80.0mm(3.15鈥? CABLES.
TIME IN SECONDS
10
1
0.1
0.01
10000
CURRENT IN AMPERES
458
w w w. l i t t e l f u s e . c o m