PD064VT5
Note 9-2 : CR =
Luminance when LCD is White
Luminance when LCD is Black
Contrast Ratio is measured in optimum common electrode voltage.
Note 9-3 : 1. Topcon BM-7 (fast) luminance meter 2擄field of view is used in the testing (after 20~30 minutes
operation).
2.Lamp current : 6 mA
3.Inverter model : TDK-347.
Note 9-4 : The definitions of response time
White
100%
90%
Brightness
10%
0%
Tr
Tf
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed,
reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:17
Black
White