UPD6600AGS Datasheet

  • UPD6600AGS

  • 4-BIT SINGLE-CHIP MICROCONTROLLER FOR REMOTE CONTROL TRANSMI...

  • 36頁

  • NEC   NEC

掃碼查看芯片數(shù)據(jù)手冊

上傳產(chǎn)品規(guī)格書

PDF預(yù)覽

PD6124A, 6600A
NOTES FOR CMOS DEVICES
1 PRECAUTION AGAINST ESD FOR SEMICONDUCTORS
Note: Strong electric field, when exposed to a MOS device, can cause destruction
of the gate oxide and ultimately degrade the device operation. Steps must
be taken to stop generation of static electricity as much as possible, and
quickly dissipate it once, when it has occurred. Environmental control must
be adequate. When it is dry, humidifier should be used. It is recommended
to avoid using insulators that easily build static electricity. Semiconductor
devices must be stored and transported in an anti-static container, static
shielding bag or conductive material.
All test and measurement tools
including work bench and floor should be grounded. The operator should
be grounded using wrist strap. Semiconductor devices must not be touched
with bare hands. Similar precautions need to be taken for PW boards with
semiconductor devices on it.
2 HANDLING OF UNUSED INPUT PINS FOR CMOS
Note: No connection for CMOS device inputs can be cause of malfunction. If no
connection is provided to the input pins, it is possible that an internal input
level may be generated due to noise, etc., hence causing malfunction. CMOS
device behave differently than Bipolar or NMOS devices. Input levels of
CMOS devices must be fixed high or low by using a pull-up or pull-down
circuitry.
Each unused pin should be connected to V
DD
or GND with a
resistor, if it is considered to have a possibility of being an output pin. All
handling related to the unused pins must be judged device by device and
related specifications governing the devices.
3 STATUS BEFORE INITIALIZATION OF MOS DEVICES
Note: Power-on does not necessarily define initial status of MOS device. Produc-
tion process of MOS does not define the initial operation status of the device.
Immediately after the power source is turned ON, the devices with reset
function have not yet been initialized. Hence, power-on does not guarantee
out-pin levels, I/O settings or contents of registers. Device is not initialized
until the reset signal is received. Reset operation must be executed imme-
diately after power-on for devices having reset function.
34

UPD6600AGS相關(guān)型號PDF文件下載

您可能感興趣的PDF文件資料

熱門IC型號推薦

掃碼下載APP,
一鍵連接廣大的電子世界。

在線人工客服

買家服務(wù):
賣家服務(wù):
技術(shù)客服:

0571-85317607

網(wǎng)站技術(shù)支持

13606545031

客服在線時間周一至周五
9:00-17:30

關(guān)注官方微信號,
第一時間獲取資訊。

建議反饋
返回頂部

建議反饋

聯(lián)系人:

聯(lián)系方式:

按住滑塊,拖拽到最右邊
>>
感謝您向阿庫提出的寶貴意見,您的參與是維庫提升服務(wù)的動力!意見一經(jīng)采納,將有感恩紅包奉上哦!