X40020, 40021
Data Sheet
March 28, 2005
FN8112.0
Dual Voltage Monitor with Integrated CPU
Supervisor and System Battery Switch
FEATURES
鈥?Dual voltage detection and reset assertion
鈥擳hree standard reset threshold settings
(4.6V/2.9V, 4.6V/2.6V, 2.9V/1.6V)
鈥擵
TRIP2
Programmable down to 0.9V
鈥擜djust low voltage reset threshold voltages
using special programming sequence
鈥擱eset signal valid to V
CC
= 1V
鈥擬onitor two voltages or detect power fail
鈥?Battery Switch Backup
鈥?V
OUT
: 5mA to 50mA from V
CC
; 250碌A(chǔ) from V
BATT
鈥?Fault detection register
鈥?Selectable power-on reset timeout
(0.05s, 0.2s, 0.4s, 0.8s)
鈥?Selectable watchdog timer interval
(25ms, 200ms, 1.4s, off)
鈥?Debounced manual reset input
鈥?Low power CMOS
鈥?5碌A(chǔ) typical standby current, watchdog on
鈥?碌A(chǔ) typical standby current, watchdog off
鈥?碌A(chǔ) battery current in backup mode
鈥?400kHz 2-wire interface
鈥?2.7V to 5.5V power supply operation
鈥?Available packages
鈥?4-lead SOIC, TSSOP
鈥?Monitor Voltages: 5V to 1.6V
鈥?Memory Security
鈥?Battery Switch Backup
鈥?V
OUT
5mA to 50mA
BLOCK DIAGRAM
APPLICATIONS
鈥?Communications Equipment
鈥擱outers, Hubs, Switches
鈥擠isk arrays
鈥?Industrial Systems
鈥擯rocess Control
鈥擨ntelligent Instrumentation
鈥?Computer Systems
鈥擠esktop Computers
鈥擭etwork Servers
X40020/21
Standard V
TRIP1
Level Standard V
TRIP2
, Level Suffix
4.6V (+/-1%)
2.9V(+/-1.7%)
-A
4.6V (+/-1%)
2.6V (+/-2%)
-B
2.9V(+/-1.7%)
1.6V (+/-3%)
-C
See 鈥淥rdering Information鈥?for more details
For Custom Settings, call Intersil.
DESCRIPTION
The X40020 combines power-on reset control, watch-
dog timer, supply voltage supervision, and secondary
supervision, and manual reset, in one package. This
combination lowers system cost, reduces board space
requirements, and increases reliability.
Applying voltage to V
CC
activates the power-on reset
circuit which holds RESET/RESET active for a period of
time. This allows the power supply and system oscilla-
tor to stabilize before the processor can execute code.
V
OUT
V2MON
+
V2 Monitor
Logic
V
TRIP2
V2FAIL
-
SDA
WP
Data
Register
Command
Decode Test
& Control
Logic
Fault Detection
Register
Status
Register
Watchdog
and
Reset Logic
V
OUT
WDO
MR
RESET
X40020
SCL
V
OUT
V
CC
(V1MON)
+
V
CC
Monitor
Logic
System
Battery
Switch
V
TRIP1
-
Power-on,
Manual Reset
Low Voltage
Reset
Generation
RESET
X40021
BATT-ON
V
OUT
V
BATT
LOWLINE
1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 1-888-352-6832
|
Intersil (and design) is a registered trademark of Intersil Americas Inc.
Copyright Intersil Americas Inc. 2005. All Rights Reserved
All other trademarks mentioned are the property of their respective owners.