VRE125 series references are designed to
operate over an extremely wide temperature
range (-55擄C to +200擄C) and still provide
excellent accuracy. The VRE125 provides a +5V
output and the VRE127 provides a 鹵5V output.
All types are available in commercial (C suffix)
and military (M suffix) models. They are
hermetically sealed and are screened for high
reliability and quality. Two accuracy grades
(standard and A) are available in both models.
The adjacent selector guide shows the limits of
the most important parameters of the
VRE125/127 series references.
SELECTION GUIDE
Max. Volt
Deviation
(-55擄C
to +150擄C)
Max. Volt
Deviation
(150擄C
to +200擄C)
Initial
Error
(Max)
Type
VRE125C
VRE125CA
VRE125M
VRE125MA
VRE127C
VRE127CA
VRE127M
VRE127MA
Output
+5V
+5V
+5V
+5V
鹵5V
鹵5V
鹵5V
鹵5V
鹵0.9mV
鹵0.6mV
鹵0.9mV
鹵0.6mV
鹵0.9mV
鹵0.6mV
鹵0.9mV
鹵0.6mV
鹵3.0mV
鹵2.0mV
鹵3.0mV
鹵2.0mV
鹵3.0mV
鹵2.0mV
鹵3.0mV
鹵2.0mV
鹵0.8mV
鹵0.4mV
鹵0.8mV
鹵0.4mV
鹵0.8mV
鹵0.4mV
鹵0.8mV
鹵0.4mV
The accuracy of the VRE125/127 series over
temperature is achieved by using Thaler
Corporation's patented multi-point compensation technique. The stability of the VRE125 series is enhanced
by using a zener diode instead of a bandgap reference, which is typically used in 5V references. Zener
diodes have better long term stability and don't suffer the significant shifts caused by temperature cycling
that bandgap references do.
Other performance parameters, such as warm-up drift and long term stability are better than competitive
models.
Superior stability, accuracy, and quality make these references ideal for high temperature applications such
as A/D and D/A converter references.
VRE125DS REV. C SEPT 1994