Rev 1 1 of 2
Front End Specifications:
(typical at T = 25藲C, nominal line, 75% load, unless otherwise specified)
Single Phase (250, 500, 750W)
AC Line Input
With Range Strap
Without Range Strap
Line Frequency
Line Inrush Current
115Vac Operation
230Vac Operation
240Vac Operation
AC Leakage Current
Power Factor (at full load)
Holdup Time (at full load)
Low Line
Nominal Line
AC Fail Warning Time
(at full load)
Strappable 115/230Vac
90 Vac to 135Vac
180 Vac to 270Vac
47 to 63 Hz (鈥淐鈥?Grade)
47 to 440 Hz (鈥淚鈥?Grade)
35A at peak line
67A at peak line
52A at peak line
1.9 mA max. at 250Vac,
63 Hz (鈥淐 鈥?Grade)
0.52 to 0.65 (at low line input)
250W (60 Hz): 4 ms min.
500, 750W (60 Hz): 7 ms min.
250W (60 Hz): 27 ms min.
500, 750W (60 Hz): 29 ms. min.
250W: None
500, 750W: 6 ms min.
3.2 mA max. at 208Vac, 63 Hz
0.9 (typical at nom. line)
Three Phase (1.5, 3, 5 kW)
208 Vac +20%/鈥?0%
(Wye or Delta, 酶 to 酶)
N/A
N/A
47 to 63 Hz (鈥淐鈥?Grade)
47 to 440 Hz (鈥淚鈥?Grade)
20 ms min. (47 Hz)
5 ms min.
Called Module Enable
Product Highlights
From AC line in, to highly regulated DC
out, Vicor offers the total design solution
through a complete family of off-line front
end and DC-DC modular power components.
Vicor鈥檚 family of off-line front ends
interface VI-260 and VI-J60 series
DC-DC converters, and MegaMods, to
100, 115, 230 or 240Vac single-phase and
208Vac three-phase mains. In addition,
front ends provide conducted EMI/RFI
filtering to FCC/VDE (Class B single-
phase, Class A three-phase), transient
surge protection, active inrush limiting, a
BUS OK status output (suitable for
controlling Vicor DC-DC converter
modules via their Gate In pin) and an AC
OK status output for system use in the
event of loss of the AC line.
Module Gate Control Output
Called BUS OK
(open drain FET, non-isolated,
referenced to 鈥揇C output)
ENABLE
Active High (FET cutoff)
Vds max. 18V transorb clamp
Power up threshold DC bus:
250W: 216V, 鹵12%
500, 750W: 244, 鹵3.5%
Active High (FET cutoff)
Power-up threshold >227V
Vds max: 15V zener clamp
ENABLE
Inactive state (DC BUS <190V 鹵5%) Inactive state (DC BUS <187Vdc)
Current sinking 100 mA @
Current sinking 100 mA @
.3 Vds max., threshold DC bus
.3Vds max.
250W: 172V, 鹵16%
500, 750W: 175V, 鹵3.5%
500, 750W only
AC OK and BUS OK
Operating Temperature
(Free Convection)
C: 0擄C to +50擄C (750W: +45擄C)
I: -20擄C to +50擄C (750W: +45擄C)
AC OK and BUS OK Status
Outputs (optically isolated,
transistor output; 500W,
750W only)
Off State Breakdown
Voltage
On State Voltage
On State Current
On State Threshold
(no load)
Off State Threshold
(load dependent)
Conducted EMI/RFI
Dielectric Withstand
70Vce max.
.4Vce (sat.) max. at 1 mA
15 mA max.
80-89Vac
85-76Vac
VDE 0871/FCC part 15, Class B
AC line (both phases)
to GND or case
1.5 kVAC; 2121Vdc
70 Vce max.
.4 Vce (sat.) max. at 1 mA
15 mA max.
>210 Vdc/187Vac
<205 Vdc/<182Vac
VDE 0871/FCC part 15, Class A
AC line (all phases)
to GND orcase
1.5 kVAC; 2121Vdc
IEC 61000-4-5, Level 3
1.2/50 碌s, 2 kV,
either polarity
0 to 360 degree phase angle with
respect to AC line
1.2/50 碌s, 1 kV pulse,
either polarity
0 to 360 degree phase angle with
respect to AC line
Storage Temperature
-40擄C to +80擄C
Transient Surge Withstand
IEC 61000-4-5, Level 3
Capability (with no disruption
of function)
Common Mode
1.2/50 碌s, 2 kV,
either polarity
0 to 360 degree phase angle with
respect to AC line
Normal Mode
1.2/50 碌s, 1 kV pulse,
either polarity
0 to 360 degree phase angle with
respect to AC line