鈥?/div>
Delay Time Range: 3.7s to 20h
RC Oscillator Determines Timing Characteristics
Relay Driver with Z-diode
Debounced Input for Toggle Switch
Two Debounced Inputs: ON and OFF
Load-dump Protection
RF Interference Protected
Protection According to ISO/TR7637-1 (VDE 0839)
Inputs Switched to V
Batt
1. Description
The bi-polar long-term timer U6046B is designed to automatically limit the operation
time of high loads in the harsh automotive environment with a preset delay time. With
the power-on-reset function the timers guarantee that current consuming devices are
not operated unintentionally.
The delay time can be interrupted manually, but a retrigger function is not provided.
Figure 1-1.
Block Diagram with External Circuit
47
碌F
V
stab
V
S
Rear Window
Heating Timer/
Long-term
Timer
U6046B
C
2
OSC 6
R
2
C
1
R
1
7
8
510
鈩?/div>
V
Batt
Oscillator
Stabilization
Power-on reset
Load-dump detection
1
GND
Frequency divider
3
ON
4
OFF
5
TOGGLE
Debouncing
Mono-flop
Relay control
output
2
OUT
Rev. 4674B鈥揂UTO鈥?9/05