**Approvals: UL Recognition, Std. 248-14, Guide #JDYX2, File #E19180; CSA Certification, C22.2 No. 248.14, Class #1422-01, File #53787.
NOTE: SFT 12.5A is UL recognized on AC Only.
1. Interrupting ratings were measured at 100% power factor on AC, and a time constant less than 1ms on DC.
2. Voltage drop was measured at 25擄C 鹵 3擄C ambient temperature at rated current with device mounted on a circuit trace.
3. I
2
t measured at 50 amp, 125 VAC, .95PF, random closing angle; 300 amps, 125 VDC, TC<1ms.
4. Electrical characteristics for 12.5 amp to be determined.
5. Device designed to carry 125% of rated current for one hour minimum. An operating current of 80% or less of rated current is recommended, with further derating
required at elevated ambient temperatures.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 VAC, 75-1500 VDC). Refer to BIF document #8002 or contact
Bussmann Application Engineering at 314-527-1270 for more information.