鈩?/div>
FEATURES
n
n
n
n
n
BIDIRECTIONAL CROWBAR PROTECTION
BETWEEN TIP AND GND, RING AND GND
AND BETWEEN TIP AND RING.
PEAK PULSE CURRENT :
I
PP
= 30A for 10/1000碌s surge.
HOLDING CURRENT :
I
H
= 150mA.
AVAILABLE IN SO8 PACKAGES.
LOW DYNAMIC BREAKOVER VOLTAGE.
SO-8
DESCRIPTION
Dedicated to telecommunication equipment
protection, these devices provide a triple
bidirectional protection function.
They ensure the same protection capability with
the same breakdown voltage both in longitudinal
mode and transversal mode.
A particular attention has been given to the internal
wire bonding. The 鈥?-point鈥?configuration ensures
a reliable protection, eliminating overvoltages
introduced by the parasitic inductances of the
wiring (Ldi/dt), especially for very fast transient
overvoltages.
Dynamic characteristics have been defined for
several types of surges, in order to meet the SLIC
maximum ratings.
COMPLIES WITH BELLCORE STANDARDS :
TR-NWT-001089:
10/1000碌s
2/10碌s
2/10碌s
(second level)
with line series resistors of 56鈩?/div>
1000V
2500V
(first level)
5000V
SCHEMATIC DIAGRAM
TIP
1
GND
2
GND
3
RING
4
8
TIP
7
GND
6
GND
5
RING
TM: ASD is trademarks of STMicroelectronics.
October 2003 - Ed: 7A