General Purpose Relays
Safety Relay SR6
I
I
I
I
I
6 pole safety relay with either
4 NO+2 NC or 3 NO+3 NC or 5 NO+1 NC contacts
Forcibly guided contacts according to EN50205
Rated current 8 A
coil power 800 mW or 1200 mW
RoHS compliant (Directive 2002/95/EC)
Applications
Emergency shut-off, press control, machine control, elevator
and escalator control, safety modules
F0206-DS
Approvals
(in preperation)
V
REG.-Nr.
of
128935,
Z
request
T
E214024,
Technical data approved types on
Contact data
3 NO contacts and 3 NC contacts
4 NO contacts and 2 NC contacts
5 NO contacts and 1 NC contact
Contact set
single contact, forcibly guided
type A according to EN 50205
Type of interruption
micro disconnection
Rated current
8A
Rated voltage / max.switching voltage AC
240 / 400 VAC
Maximum breaking capacity AC
2000 VA
Contact material
800 mW version
AgSnO
2
+ 0,2 渭m Au
1200 mW version
AgSnO
2
Minimum contact load
10 mA / 5 V
Contact resistance
w
100 mOhm / 1 A / 24 VDC
w
20 Ohm / 10 mA / 5 VDC
Mechanical endurance
10x10
6
cycles
Rated frequency of operation with / without load
6 min
-1
/ 150 min
-1
Contact configuration
Contact ratings
Type
SR6 NO contact
SR6 NC contact
SR6 NO contact
SR6 NO contact
Load
8A, 250VAC, resistiv, 70擄C, EN61810-1
8A, 250VAC, resistiv, 70擄C, EN61810-1
5A, 250VAC, AC15, 70擄C, EN60947-5-1
5A, 24VDC, DC13, 25擄C, EN60947-5-1
Cycles
50x10
3
20x10
3
50x10
3
45x10
3
Coil data
800 mW
1200 mW
Rated coil voltage range DC coil
5...110 VDC
Coil power DC coil
appr. 800 mW
appr. 1200 mW
Operative range
2
Coil versions, 800 mW, DC-coil
Coil code
Nominal
Pull-in
Release
Coil
Rated coil
Order. code voltage
voltage
voltage
resistance
power
block 4
VDC
VDC
VDC
c
mW
K05
5
3.8
0.5
31+10%
806
K06
6
4.5
0.6
45+10%
800
K09
9
6.8
0.9
101+10%
802
K12
12
9.0
1.2
180+10%
800
K18
18
13.5
1.8
405+10%
800
K21
21
15.8
2.1
551+10%
800
K24
24
18.0
2.4
720+10%
800
K36
36
27.0
3.6
1620+10%
800
K40
40
30.0
4.0
2000+10%
800
K48
48
36.0
4.8
2880+10%
800
K60
60
45.0
6.0
4500+10%
800
K85
85
63.8
8.5
9031+10%
800
L10
110
82.5
11.0
15130+10%
800
All figures are given for coil without preenergization, at ambient temperature +23擄C
Other coil voltages on request
1
Datasheet
Rev. FC1
Issued 2006/03
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
鈥楽chrack鈥?section.
Specifications subject to
change.