鈼?/div>
Single Output up to 20A
Dual Outputs Total Current up to 15A
up to 100% Load Imblance
Input/Output 1.6kVDC Isolation
Adjustable Output Voltage, Independently
Regulated Outputs
No Minimum Load
Industry Standard Footprint
Halt Tested
Compact 61.0 x 57.91 x 12.7mm Package
High Efficiency to 90%
INNOLINE
DC/DC-Converter
RP75-S_DI
Series
75 Watt
Isolated
Single
&
Dual Output
Selection Guide
Part
Number
Input
Voltage
(VDC)
36 鈥?75
36 鈥?75
36 鈥?75
36 鈥?75
36 鈥?75
Input
Voltage
(VDC)
36 鈥?75
36 鈥?75
36 鈥?75
36 鈥?75
Output
Voltage
(VDC)
1.8
2.5
3.3
5
15
Output
Current
(A)
20
20
20
15
5
Line
Load
Regulation Regulation
(mV)
(mV)
4
5
7
10
30
Output
Current
I1
(A)
15
15
15
15
I2
(A)
15
15
15
15
6
8
10
15
45
Input Efficiency
Current
(A)
%
915
1255
1618
1838
1860
86
88
90
90
90
Single Output
RP75-481.8S
RP75-482.5S
RP75-483.3S
RP75-4805S
RP75-4815S
Part
Number
Dual Output
RP75-483.305DI
RP75-483.32.5DI
RP75-48051.8DI
RP75-483.31.8DI
Output
Voltage
V1
V2
(VDC)
(VDC)
5
3.3
5
3.3
3.3
2.5
1.8
1.8
Line
Load Efficiency
Regulation Regulation
(mV)
7/10
7/5
10/4
7/4
(mV)
10/15
10/8
10/15
10/6
%
88
81
85
81
Notes:
1. Maximum output deviation is 10% inclusive of remote sense. If remote sense is not being used,
the +Vsense should be connected to its corresponding +Vout and likewise the -Vsense should be connected
to its corresponding -Vout..
2. Measured with a 1碌F M/C and a 10uF M/C(for dual outputs) or 1碌F M/C and a 10碌F T/C(for single outputs).
3. An external filter capacitor is required for normal operation. The capacitor should be capable of handing 1A ripple
current for 48V models. RECOM suggest: Nippon chemi-con KMF series, 220碌F/100V, ESR 90m
鈩?/div>
.
4. The negative / positive logic and length are optional ( see table ). The pin voltage is referenced to negative input.
5. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at Tc=40擄C.
(Ground fixed and controlled environment)
6. Heat sink is optional and P/N: 7G-0021, 7G-0022, 7G-0023, 7G-0024.
7. The RP75 meets level A and level B conducted emissions only with external components connected before
the input pin to the converter.
8. Maximum value at nominal input voltage and full load.
9. Single:Typical value at nominal input voltage and full load.
Dual:The efficiency test condition: Nominal input voltage and both outputs current are 7.5A.
10. BASEPLATE GROUNDING:Base-plate should be grounded at one of the four screw bolts prior to operation.
11. The converter is provided by basic insulation.
12. 鈥淣鈥?for Negative remote ON/OFF.
N
13. 鈥淧鈥?for
Positive
remote ON/OFF.
P
186
July-2006
www.recom-international.com
next