鈼?/div>
Single Outputs up to 15A
Input/Output 1.6kVDC Isolation
Adjustable Output Voltage
No Minimum Load
Under -Voltage Lockout
Industry Standard Footprint
Fixed Operating Frequency
Halt Tested
Compact 61.0 x 57.91 x 12.7mm Package
High Efficiency to 91%
INNOLINE
DC/DC-Converter
RP50-S
Series
50 Watt
Single
Output
Selection Guide
Part
Number
Input
Voltage
(VDC)
18 鈥?36
18 鈥?36
18 鈥?36
18 鈥?36
18 鈥?36
36 鈥?75
36 鈥?75
36 鈥?75
36 鈥?75
36 鈥?75
Output
Voltage
(VDC)
1.8
2.5
3.3
5
15
1.8
2.5
3.3
5
15
Output
Line
Load
Current Regulation Regulation
(A)
(mV)
(mV)
15
15
15
10
3.3
15
15
15
10
3.3
4
5
7
10
30
4
5
7
10
30
6
8
10
15
45
6
8
10
15
45
Input Efficiency
Current
(A)
%
1.36
1.86
2.40
2.40
2.40
1.36
1.86
2.40
2.40
2.40
86
87
89
90
89
87
89
90
91
90
Single Output
RP50-241.8S
RP50-242.5S
RP50-243.3S
RP50-2405S
RP50-2415S
RP50-481.8S
RP50-482.5S
RP50-483.3S
RP50-4805S
RP50-4815S
Notes:
1. Maximum output deviation is 10% inclusive of remote sense. If remote sense is not being used,
the +Vsense should be connected to its corresponding +Vout
2. Measured with a 1uF M/C and a 10碌F T/C.
3. An external filter capacitor is required for normal operation. The capacitor should be capable of handing 1A
ripple current for 48V/24V models. RECOM suggests: Nippon chemi-con KMF series, 220碌F/100V, ESR 90m
鈩?/div>
.
4. The negative/ positive logic and pin length are optional ( see table ). The pin voltage is referenced to
negative input.
5. Heat sink is optional and P/N: 7G-0021, 7G-0022, 7G-0023, 7G-0024.
6. The RP50 meets level A and level B conducted emissions only with external components connected before
the input pin to the converter.
7. Maximum value at nominal input voltage and full load.
8. Typical value at nominal input voltage and full load.
9. BASEPLATE GROUNDING : Base-plate should be grounded at one of the four screw bolts prior to operation.
10. The converter is provided by basic insulation.
11. 鈥淣鈥?for Negative remote ON/OFF.
N
12. 鈥淧鈥?for
Positive
remote ON/OFF.
P
178
July-2006
www.recom-international.com
next