鈼?/div>
Single Output up to 25A
Dual Outputs Total Power up to 100W
Input/Output 1.6kVDC Isolation
Adjustable Output Voltage
Under-Voltage Lockout
No Minimum Load
Industry Standard Footprint
Fixed Operating Frequency
Halt Tested
Compact 61.0 x 57.91 x 12.7mm Package
High Efficiency to 90%
INNOLINE
DC/DC-Converter
RP100-S_DI
Series
Selection Guide
Part
Number
Input
Voltage
(VDC)
36 鈥?75
36 鈥?75
36 鈥?75
36 鈥?75
36 鈥?75
Input
Voltage
(VDC)
36 鈥?75
36 鈥?75
36 鈥?75
Output
Voltage
(VDC)
1.8
2.5
3.3
5
15
Output
Voltage
V1 / V2
(VDC)
5 / 3.3
5 / 2.5
3.3 / 2.5
Output
Current
(A)
25
25
25
20
6.66
Output
Current
I1 / I2
(A)
20 / 25
20 / 25
25 / 25
Line
Load
Regulation Regulation
(mV)
(mV)
4
5
7
10
30
Line
Regulation
V1 / V2
(mV)
25 / 16.5
25 / 12.5
16.5 / 12.5
6
8
10
15
45
Load
Regulation
V1 / V2
(mV)
25 / 16.5
25 / 12.5
16.5 / 12.5
Input
Efficiency
(8)
(9)
Current
(A)
%
1.157
1.608
2.022
2.480
2.507
86
87
90
90
90
Single Output
RP100-481.8S
RP100-482.5S
RP100-483.3S
RP100-4805S
RP100-4815S
Part
Number
100 Watt
Isolated
Single
&
Dual Output
Input Efficiency
Current
(8) (9)
(A)
2.39
2.45
2.44
%
87
85
85
Dual Output
RP100-483.305DI
RP100-482.505DI
RP100-482.53.3DI
Notes:
1. Maximum output deviation is 10% inclusive of remote sense. If remote sense is not being used,
the +Vsense should be connected to its corresponding +Vout and likewise the -Vsense should be connected
to its corresponding -Vout.
2. Single: Measured with a 1uF M/C and a 10uF T/C.
Dual: For each outputs.
3. An external filter capacitor is required for normal operation.
The capacitor should be capable of handing 1A ripple current for 48V models.
RECOM suggest: Nippon chemi-con KMF series, 220碌F/100V, ESR 90m
鈩?/div>
.
4. Single: The negative / positive logic and length are optional ( see table ).
The pin voltage is referenced to negative input.
Dual: The ON/OFF control function. There are positive logic ( standard ) and negative logic ( option ).
The pin voltage is referenced to negative input.
To order negative logic ON/OFF control add the suffix-N. ( Ex:RP100-483.305I/N )
5. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40擄C.
( Ground fixed and controlled environment )
6. Heat sink is optional and P/N: 7G-0021, 7G-0022, 7G-0023, 7G-0024.
7. The RP100 meets level A and level B conducted emissions only with external components connected before
the input pin to the converter.
8. Maximum value at nominal input voltage and full load.
9. Typical value at nominal input voltage and full load.
The dual efficiency test condition:
RP100-483.305DI @ 5V/12A and 3.3V/12A
RP100-482.505DI @ 5V/12A and 2.5V/16A
RP100-482.53.3DI @ 3.3V/18A and 2.5V/16A
10. BASEPLATE GROUNDING: Base-plate should be grounded at one of four screw bolts prior to operation.
11. The converter is provided by basic insulation.
N
12. 鈥淣鈥?for Negative remote ON/OFF.
P
13. 鈥淧鈥?for Positive remote ON/OFF.
www.recom-international.com