1000 M鈩?/div>
Measured at 500 VDC after 2 min, +23擄C
Max 12 A repetitive. Max 20 A peak for occasional
transients.
The 100% screening factory test is carried out at
3000 VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Recommended voltage
鈮?/div>
1000 VDC.
The average losses may reach 0.5 W provided the
surface temperature does not exceed + 85擄C. For
maximum permitted power dissipation vs temperature,
see derating curves.
Curve
1
1
2
3
4
Dimensions
B = 7.3
B = 8.5
B = 9.0
B = 11.3
B = 10.6
P
max
W
0.5
R
d = 0.8 for p = 15.2 and 20.3
1.0 for p = 25.4
C
l: standard: 30 +5/-0 mm
option: short leads, tolerance +0/-1 mm
(standard 6 mm, code R06)
Other lead lengths on request.
Pulse current
Test voltage between
terminals
In DC applications
Power ratings
1
2 3
4
0
T
amb
40
50
60
70
80
85
擄C
Maximum allowable power dissipation vs
ambient temperature and case sizes.
198
next