PH150S280 Specifications
NEMIC-LAMBDA
*
PH150S
PH150S
ITEMS
280-3.3
280-5
1 Nominal Output Voltage
V
3.3
5
2 Maximum Output Current
A
30
30
3 Nominal Output Power
W
99
150
72
82
4 Efficiency (Typ)
(鈭?) %
5 Input Voltage Range
- 200 ~ 400VDC
280VDC input
A
0.47
0.65
0.63
0.63
0.61
0.61
6 Input Current (Typ)
360VDC input
A
(at full load)
0.37
0.51
0.49
0.49
0.48
0.48
7 Output Voltage Accuracy
(鈭?) %
鹵
1%
8 Output Voltage Range
(鈭?) %
鹵
10% (At 280VDC input)
9 Maximum Ripple & Noise
100
100
150
150
240
280
(鈭?) mV
10 Maximum Line Regulation
20
20
48
60
96
112
(鈭?) mV
40
40
96
120
192
224
11 Maximum Load Regulation
(鈭?) mV
12 Over Current Protection
(鈭?) - 105% ~ 150%
13 Over Voltage Protection
(鈭?) - 165~240% 125% ~ 145%
14 Remote Sensing
- Possible
15 Remote ON/OFF Control
(*8) - Possible (Short : ON, Open : OFF)
16 Parallel Operation
- -----
- Possible
17 Series Operation
(鈭?)
19 Operating Temperature
(鈭?) - -20 ~ +85擄C (Baseplate) Ambient Temperature min = -20擄C
20 Operating Humidity
-
30 ~ 95%RH (No dewdrop)
21 Storage Temperature
- -40 ~ +85擄C
22 Storage Humidity
-
10 ~ 95%RH (No dewdrop)
23 Cooling
(鈭?) - Conduction Cooled
24 Temperature Coefficient
- 0.02% / 擄C
25 Withstand Voltage
- Input - Baseplate : 2.5kVAC (20mA) for 1 minute.
Input - Output : 3.0kVAC (20mA) for 1 minute.
Output - Baseplate : 500VDC for 1 minute.
26 Isolation Resistance
- More than 100M鈩?at 25擄C and 70%RH Output - Baseplate : 500VDC
27 Vibration
- At no operating, 10 ~ 55Hz amplitude (sweep for 1minute)
0.825mm constant (Maximum 5G) X,Y,Z 1hour each.
28 Shock
- Less than 20G (In Package)
29 Safety Standard
UL1950
- Approved by UL (excluding PH150S280-3.3)
CSA234
- Approved by CSA (excluding PH150S280-3.3)
EN60950
- Approved by BSI (excluding PH150S280-3.3)
30 Weight (Typ)
g 150g
mm
72 x 12.7 x 86 (Refer to Outline Drawing)
31 Size (WxHxD)
* Read instruction manual carefully, before using the power supply unit.
MODEL
=NOTES=
鈭?.
At 280VDC and maximum output current.
鈭?.
200 ~ 400VDC input, constant load.
鈭?.
No load ~ Full load, constant input voltage.
鈭?.
Constant current limiting with automatic recovery.
鈭?.
Inverter shut-down method, manual reset.
鈭?.
Ratings - Refer to Derating Curve on the right.
- Load (%) is percent of maximum output current.
鈭?.
Heatsink has to be chosen according to instruction manual.
鈭?.
Refer to instruction manual.
鈭?.
External components are needed for operation.
(Refer to basic connection and instruction manual)
Derating Curve
100
Load (%)
80
60
40
20
0
-20
0
20
40
60
85
80 100
C095-01-01B
* : For delivery, contact to our sales office.
*
*
PH150S
PH150S
PH150S
PH150S
280-12
280-15
280-24
280-28
12
15
24
28
12.5
10.0
6.3
5.4
150
150
151.2
151.2
85
85
88
88
Baseplate Temperature (擄C)