DB LECTRO INC
N 9 3 2
31脳23
Features
n
n
Switching capacity up to 15A.
Suitable for automation system and auxiliary automobile etc.
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation
Electrical
life
Mechanical
1C
Au AgNi
15A/14VDC
210W
15VDC
50m鈩?Max.
10
5
10
7
Max. Switching Current:15A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
Coil Parameter
Coil voltage
VDC
Pickup
voltage
VDC(max)
(67%of rated
voltage )
Release
voltage
VDC(min)
(10% of rated
voltage)
Operate
Time
ms
Max.
Release
Time
ms
Max.
Coil resistance
鈩β?0%
Coil power
consumption
W
Rated
Max.
12
15.6
120
8
1.2
1.2
10
8
CAUTION
:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Operation condition
Insulation Resistance
1)
Dielectric Strength
1)
Between contacts
Between contact and coil
100M鈩?min (at 500VDC)
50Hz 500V
50Hz 500V
Item 7 of IEC255-5
Item 6 of IEC255-5
Item 6 of IEC255-5
Shock resistance
100m/s
2
11ms
IEC68-2-27 Test Ea method 1
Vibration resistance
10~55Hz double amplitude 1.5mm
IEC68-2-6 Test Fc
Terminals strength
8N
IEC68-2-21 Test Ua2
Solderability
IEC68-2-20 Test Ta method 1
230 潞C
鹵
2 潞C 10
鹵
0.5s
Ambient Temperature
-40~125 潞C
Relative Humidity
85% (at 40 潞C)
IEC68-2-3Test Ca
Mass
31g
Note: 1). When testing, coil terminals shall be connect ,if coil transient suppression is installed in relay .
Qualification inspection:
Perform the qualification test as specified in the table IV of IEC255-19-1 and minimum sample size 24.
107