鈥?/div>
Auto ranging input
Remote sense
Remote inhibit
Power fail
Single wire current sharing
Built-in EMI filter
Low output ripple
Adjustable output
135 khz switching frequency
Overvoltage protection
Overload protection
Optional cover (-C suffix).
Safety ground
leakage current
Output
Maximum power
110 W convection (75 W with cover)
150 W with 30 CFM forced air
(130 W with cover)
鹵5% minimum
20 ms @ 110 W load, 115/230 VAC
nominal line
Short circuit protection. Case overload
protected @ 110% to 145% above
peak rating
5 V output: 5.7 to 6.7 VDC. Other
outputs 10% to 25% above nominal
output
TTL Logic signal goes high 50-150
msec after 5 V output. It goes low at
least 3 ms before loss of regulation.
Requires an external TTL high signal to
inhibit outputs.
Compensates for 0.5 V lead drop
minimum, will operate without
remote sense connected. Reverse
connection protected.
Adjustment range
Hold-up time
Overload protection
Overvoltage protection
Environmental
Operating temperature: 0擄 to 50擄C ambient;
derate each output at 2.5% per degree from 50擄
to 70擄C
Electromagnetic susceptibility: Designed to
meet IEC 801, -2, -3, -4, -5,-6, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40擄 to 85擄C
Temperature coefficient: 鹵.04% per 擄C
MTBF demonstrated: >550,000 hours at full load
and 25擄C ambient conditions
Logic Control
Power Failure
Remote inhibit
Remote sense
Safety
VDE
UL
CSA
NEMKO
BABT
CB
CE
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 Level 3
EN 60950/EMKO-TUE
(74-sec) 203
EN60950/BS7002
Certificate and report
Mark (LVD)
11774-3336-1260 (LC#88585)
EI32002
LR53982
P95102999
607019
2062
112
America鈥檚 (USA): 1-888-41-ASTEC
Europe (UK): 44 (1384) 842-211
Asia (HK): 852-2437-9662