VDE
SLIM POWER RELAY WITH
HIGH INRUSH CURRENT
CAPABILITY
2. High insulation resistance between
contact and coil
1) Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch
(In compliance with IEC65)
2) Surge withstand voltage between con-
tact and coil: 10,000 V or more
3. High noise immunity realized by the
card separation structure between
contact and coil
4. Popular terminal pitch in AV equip-
ment 鏗乪ld
mm
inch
16.5
.650
COM
Coil
N.O.
20
.787
1
.039
7.5
.295
1
.039
LK-RELAYS
Creepage distance and clear-
ances in compliance with IEC65
24.0
.945
11.0
.433
25.0
.984
Card
Partition wall
mm
inch
FEATURES
1. High inrush current capability
1) Operating load capability:
inrush 100 A, steady 5 A
2) UL/CSA, TV-5
5. Space-saving slim type
Base area: Width 11
脳
Length 24 mm
Width .433
脳
Length .945 inch
6. Conforms to the various safety stan-
dards
UL, CSA, VDE, T脺V, SEMKO, SEV, BSI
approved
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Nominal switching capacity
Rating
Max. switching power
(resistive
Max. switching voltage
load)
Max. switching current
Expected Mechanical (at 180 cpm)
life (min. Electrical (at 20 cpm)
ope.)
(at rated load)
1 Form A
Max. 100 m
鈩?/div>
Silver alloy
5 A 277 V AC, 5 A 30 V DC
1,385 VA, 150 W
277 V AC, 30 V DC
5A (AC), 5 A (DC)
2
脳
10
6
10
5
Characteristics
Max. operating speed
Initial insulation resistance*
1
Initial
Between open contacts
breakdown
Between contacts and coil
voltage*
2
Initial surge voltage between con-
tact and coil*
3
Operate time*
4
(at nominal voltage)
Release time (without diode)*
4
(at nominal voltage)
Temperature rise (at 70
擄
C)
Shock
resistance
Vibration
resistance
Functional*
5
Destructive*
6
Functional*
7
Destructive
20 cpm
Min. 1,000 M
鈩?/div>
(at 500 V DC)
1,000 Vrms for 1 min
4,000 Vrms for 1 min
Min. 10,000 V
Approx. 7 ms (at 20
擄
C
68
擄
F)
Approx. 2 ms (at 20
擄
C
68
擄
F)
Max. 35
擄
C with nominal coil voltage
at 5A contact carrying current
(resistance method)
Min. 200 m/s
2
Min. 1,000 m/s
2
10 to 55 Hz
at double amplitude of 1.5 mm
10 to 55 Hz
at double amplitude of 1.5 mm
鈥?0 to +70
擄
C
-40 to +158
擄
F
5 to 85%R.H.
86 to 106 kPa
Approx. 12 g .42
oz
Coil
Nominal operating power
Remarks
* Speci鏗乧ations will vary with foreign standards certi鏗乧ation ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of
鹵
1.2
脳
50
碌
s according to JEC-212-1981
*
4
Excluding contact bounce time.
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10
碌
s
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10
碌
s
*
8
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
530 mW
Conditions for operation,
Ambient temp.
transport and storage*
8
Humidity
(Not freezing and condens-
Air pressure
ing at low temperature)
Unit weight
TYPICAL APPLICATIONS
鈥?AV equipment: TV鈥檚, VTR鈥檚, etc.
鈥?OA equipment
鈥?HA equipment
ORDERING INFORMATION
Ex.
LK
1a
F
鈥?/div>
24V
Coil voltage (DC)
5, 9, 12, 24 V
Contact arrangement
1a: 1 Form A
Protective construction
F: Flux-resistant type
UL/CSA, T脺V, SEMKO, TV-5 approved type is standard.
(Note) Standard packing Carton: 100 pcs. Case: 500 pcs.
59
next