A.S.D.鈩?/div>
FEATURES
s
s
s
s
s
s
Dual line programmable transient voltage
suppressor
Wide negative firing voltage range:
V
MGL
= -150 V max.
Low dynamic switching voltages: V
FP
and V
DGL
Low gate triggering current: I
GT
= 5 mA max
Peak pulse current: I
PP
= 15 A (10/1000
碌s)
Holding current: I
H
= 150 mA min
DESCRIPTION
This device has been especially designed to
protect 2 new high voltage, as well as classical
SLICs, against transient overvoltages.
Positive overvoltages are clamped by 2 diodes.
Negative surges are suppressed by 2 thyristors,
their breakdown voltage being referenced to -V
BAT
through the gate.
This component presents a very low gate
triggering current (I
GT
) in order to reduce the cur-
rent consumption on printed circuit board during
the firing phase.
BENEFITS
Trisils are not subject to ageing and provide a fail
safe mode in short circuit for a better protection.
Trisils are used to help equipment to meet various
standards such as UL1950, IEC950 / CSA C22.2,
UL1459 and FCC part68. Trisils have UL94 V0
resin approved (Trisils are UL497B approved (file:
E136224)).
SO-8
FUNCTIONAL DIAGRAM
TIP 1
1
8
RING 1
GATE
2
7
GND
GATE
3
6
GND
TIP 2
4
5
RING 2
March 2002 - Ed: 1A
1/8