鈥?/div>
Sealed
File No.:116934
File No.:CH0031853-99
CONTACT DATA
Contact Arrangement
Initial Contact Resistance Max.
Contact Material
Contact Rating (Res. Load)
Max. switching voltage
Max. switching current
Max. switching power
UL/CUR rating
16A
3000VA/ 4000VA
16A
12A
8A
16A
VDE
rating
Mechanical life
Electrical life
12A
8A
10A/ 24VDC
1A 1B 1C
2A 2B 2C
Silver alloy
12A/ 16A 250VAC 8A 250VAC
8A 24VDC
440VAC
8A
2000VA
277VAC
277VAC
277VAC
250VAC
250VAC
250VAC
1 x 10
7
OPS
1 x 10
5
COIL
Coil power
0.4W
50m (at 1A 6VDC)
COIL DATA
Nominal
Voltage
VDC
5
6
12
24
48
60
110
Pick-up
Voltage
VDC
3.50
4.20
8.40
16.80
33.60
42.00
77.00
Drop-out Coil Current
(at 20 )
Voltage
mA
VDC
0.5
0.6
1.2
2.4
4.8
6.0
11.0
80.0
66.7
33.3
16.7
8.30
8.00
4.30
Coil
Resistance
62
90
360
1,440
5,760
7,500
25,200
10%
10%
10%
10%
15%
15%
15%
General Purpose Power Relays
JQX-115F
OPS
CHARACTERISTICS
Initial Insulation Resistance
Dielectric
Strength
Between coil and Contacts
Between open contacts
Between contact sets
1000M (500 VDC)
5,000VAC 1min.
1,000VAC 1min.
2,500 VAC 1min.
7ms
3ms
55
100 m/s
2
1000m/s
2
10 to150 Hz 10g/5g
35% to 85%
-40
to +70
PCB
13.5g
Sealed & Unsealed
Operate time (at nomi. Volt.)
Release time (at nomi. Volt.)
Temperature rise (at nomi. Volt.)
Shock Resistance
Functional
Destructive
Vibration Resistance
Humidity
Ambient temperature
Termination
Unit weight
Construction
HONGFA RELAY
ISO9001/QS9000/ISO14000
CERTIFIED
74