JGC-4F/24D1T Datasheet

  • JGC-4F/24D1T

  • SOLID STATE RELAY

  • 2頁

  • ETC

掃碼查看芯片數據手冊

上傳產品規(guī)格書

PDF預覽

JGC-4F
SOLID STATE RELAY
Features
File No.:
E133481
鈥?/div>
DC
鈥?/div>
600
input-AC output for 2A load at 25
Volt blocking voltage
鈥?/div>
Photo
File No.:
R2024431
isolation
鈥?/div>
Built-in snubber
鈥?/div>
Zero
cross or random turn-on
circuit board mount
鈥?/div>
Printed
File No.:
CH0032705-2002A
INPUT
(TA = 25鈥)
05D
Control voltage range
12D
24D
05D
Must operate voltage
12D
24D
Must release voltage
Max. input current
4 to 6VDC
9.6 to 14.4VDC
19.2 to 28.8VDC
4VDC
9.6VDC
19.2VDC
1.0VDC
max.
max.
max.
min.
10mA
DESCRIPTION
This SPST-NO printed circuit board mount SIP SSR provides AC output
switching in a high density package.The JGC-4F's DC input is compatible
with 5, 12 and 24V logic systems .All models include an internal
snubber.The relays provide 2000Vrms opto-isolation,between input and
output. Encapsulation,thermally conductive epoxy.
PRECAUTIONS
1. Terminal arrangement
1
output
OUTPUT
Load voltage range (@47 to 63Hz)
Load current range
Max. surge current (10ms)
Max. leakage current
Max. on-state voltage drop
Max. turn-on time
Max. turn-off time
Transient overvoltage
Min. off-state dv/dt
Zero-crossover voltage
Min. power factor
Zero cross turn-on
Random turn-on
75 to 264VAC
0.1 to 2A
1.5mA
1.5VAC
10ms
1ms
10ms
600Vpk max.
100V/碌s min.
15V max.
0.5
input
load
AC line
0
2
3(+)
180
Pulse width
Input signal
25Apk
4(-)
Input signal turn off
Minimum 200碌s
2.
Soldering must be completed within 10 seconds at 260
or within 5 seconds at 350
or less.
or less
3.
The SSR case serves to dissipate heat. Install the relays so that they
are adequately ventilated. If poor ventilation is unavoidable, reduce the
load current by half.
4.
The input circuitry does not incorporate a circuit protecting the SSR
from being damaged due to a reversed connection. Make sure that the
polarity is correct when connecting the input lines.
5.
When using the JGC-4F series for an AC load with a peak voltage of
more than 450V,connect the load terminals of the relay to an inrush
absorber(varistor). The recommended varistor voltage, 440 to 470V.
6.
The load terminals are internally connected to a snubber circuit that
absorb noise. However, if wiring from these terminals is laid with or
placed in the same duct as high-voltage or power
lines, noise may
be induced, causing the SSR to operate irregularly or malfunction.
7.
When using the JGC-4F series in phase control applications, at a
phase control angle close to 180 degrees the relay's input signal turn
off at the trailing edge of the AC sine wave must be limited to end
200碌s before AC zero cross. This assures
half cycle.
that the relay has time
to switch off. Shorter times may cause loss of control at the following
Solid State Relays JGC-4F
GENERAL
Dielectric strength ( input to output )
2000VAC min., 50/60Hz 1min.
Insulation resistance
Max. Capacitance
( input to output )
Vibration durability
Shock durability
Operating
Ambient
temperature Storage
Ambient Humidity
Unit weight
1000M , min. (at 500VDC)
5pF
10 to 55HZ Double amplitude 1.5mm
1000m/s
2
-30
-30
to +80
to +100
45% to 85%
6g
HONGFA RELAY
ISO9001/QS9000/ISO14000
CERTIFIED
176

JGC-4F/24D1T相關型號PDF文件下載

掃碼下載APP,
一鍵連接廣大的電子世界。

在線人工客服

買家服務:
賣家服務:
技術客服:

0571-85317607

網站技術支持

13606545031

客服在線時間周一至周五
9:00-17:30

關注官方微信號,
第一時間獲取資訊。

建議反饋

聯系人:

聯系方式:

按住滑塊,拖拽到最右邊
>>
感謝您向阿庫提出的寶貴意見,您的參與是維庫提升服務的動力!意見一經采納,將有感恩紅包奉上哦!