HVL 900
AC Controller
with Isolated Water Flow
Preliminary data
1
7
6
I
RMS
= 900 A
V
RRM
= 1200-1800 V
V
RSM
V
DSM
V
1300
1500
1700
1900
V
RRM
V
DRM
V
1200
1400
1600
1800
Type
HVL 900 - 12io1
HVL 900 - 14io1
HVL 900 - 16io1
HVL 900 - 18io1
5
4
2/3
Symbol
I
RMS
I
TSM
, I
FSM
Test Conditions
T
Water
= 17擄C; watervolume = 4 l/min
T
VJ
= 45擄C;
V
R
= 0
T
VJ
= T
VJM
V
R
= 0
t = 10 ms (50 Hz)
t = 8.3 ms (60 Hz)
t = 10 ms (50 Hz)
t = 8.3 ms (60 Hz)
t = 10 ms (50 Hz)
t = 8.3 ms (60 Hz)
t = 10 ms (50 Hz)
t = 8.3 ms (60 Hz)
Maximum Ratings
900
9200
10100
8000
8800
423 000
423 000
320 000
321 000
100
A
A
A
A
A
A
2
s
A
2
s
As
A
2
s
A/ms
2
Features
q
q
q
q
Isolation between water and electrical
connections with Direct copper
bonded Al
2
O
3
-ceramic
Planar passivated chips
Isolation voltage 3600 V~
Keyed gate/cathode twin pins
I
2
t
T
VJ
= 45擄C
V
R
= 0
T
VJ
= T
VJM
V
R
= 0
Applications
q
q
Large resistance welding equipment
Large electroplating equipment
(di/dt)
cr
T
VJ
= T
VJM
repetitive, I
T
= 960 A
f =50 Hz, t
P
= 200
ms
V
D
= 2/3 V
DRM
I
G
= 1 A,
di
G
/dt = 1 A/ms
T
VJ
= T
VJM
; V
DR
= 2/3 V
DRM
R
GK
=
樓;
method 1 (linear voltage rise)
T
VJ
= T
VJM
I
T
= I
TAVM
t
P
= 30
ms
t
P
= 500
ms
(dv/dt)
cr
P
GM
P
GAV
V
RGM
T
VJ
T
VJM
T
stg
V
ISOL
Weight
1000
120
60
20
10
-40...+140
140
-40...+125
V/ms
W
W
W
V
擄C
擄C
擄C
V~
V~
g
50/60 Hz, RMS
I
ISOL
攏
1 mA
t = 1 min
t=1s
3000
3600
1300
Typical including screws
漏 2000 IXYS All rights reserved
1-3
013
Data according to IEC 60747 refer to a single thyristor unless otherwise stated.
IXYS reserves the right to change limits, test conditions and dimensions