鉁?/div>
3鈥?Six-Sided Metal Case
2-Year Warranty
700,000-Hour Minimum MTBF
Nominal
Max.
Input
DC
Output Output Line/
Input Voltage
Min.Nom.Max. Current Output Current Voltage Load Effi-
(V) (V) (V)
(A) Output (V)
(A) Tolerance Reg. ciency
C
HARACTERISTICS
EMI Suppression ..........................Pi input filter, standard.
Base-Plate Temperature...............Operating temperature of +100擄C,
max.with built-in thermal shutdown.
Isolation Voltage ...........................D-input models: 1500V, input to output,
for one minute. A- and B-input models:
850V, input to output, for one minute.
Output Adjustment........................Primary output adjustable 鹵10%.
Continuous Output Power ............HD1-30 and HD3-30 total output
power should not exceed 30W. HD1-
40 and HD3-40 total output power
should not exceed 40W. Maximum
output current for individual outputs of
triple output models appear in the rat-
ings table.
Minimum Load Requirement ........Single output models, no minimum.
Triple output models, 150 mA, mini-
mum on 5V output, 50 mA, minimum,
on auxiliary outputs.
Output Noise and Ripple ..............5V output, 50 mVpp, maximum. 12V
and 15V outputs, 75 mVpp, maxi-
mum. (See Note 2.)
Short-Circuit Protection ................Cycle-by-cycle current limiting.
Over-Voltage Protection ...............V1 output only: 125% of rated output,
typical. Single output models with 5V
outputs and all triple output models
have latching OVP; R
ESET
= 0V. All
other models are diode protected.
Under-Voltage Lockout.................Nom. Input
Off (Typ.) On (Typ.)
12V
7.5V
8.5V
24V
16.5V
17.5V
48V
34.0V
35.5V
Transient Response .....................200 碌s recovery after half-load to full load
step change to within 1% of the regulation
band with no more than 5% deviation.
Frequency of Operation ...............300 kHz.
Remote Shutdown........................CMOS and open-collector TTL com-
patible: ON = 2.4V to V
IN
(
MAX
); OFF
= 0.8V or less. Logic reference is -V
IN
.
Temperature Range......................-40擄C to +85擄C (ambient). See
Package Power De-Rating graph.
Temperature Coefficient ...............鹵0.02%/擄C over the entire operating
temperature range.
Relative Humidity .........................0 to 95%, non-condensing.
Altitude .........................................0 to 10,000 feet.
Cooling .........................................Convection cooling is adequate.
Moving air is recommended for opera-
tion in a confined area. See Package
Power De-Rating graph.
Storage Temperature....................-40擄C to +100擄C.
Storage Humidity..........................0 to 95%, non-condensing.
Mean Time Between Failures.......>700,000 hours. (See Note 4.)
Model
DC-DC 30W Singles
HD1-30-5A
HD1-30-5B
HD1-30-5D
HD1-30-12A
HD1-30-12B
HD1-30-12D
HD1-30-15A
HD1-30-15B
HD1-30-15D
9.0 12
18 24
36 48
9.0 12
18 24
36 48
9.0 12
18 24
36 48
25
36
75
25
36
75
25
36
75
鈥?/div>
3.16
1.52
0.75
3.09
1.51
0.75
3.01
1.51
0.73
V1 5.0
V1 5.0
V1 5.0
V1
V1
V1
V1
V1
V1
12
12
12
15
15
15
6.00
6.00
6.00
2.50
2.50
2.50
2.00
2.00
2.00
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
0.3% 79%
0.3% 82%
0.3% 83%
0.3% 81%
0.3% 83%
0.3% 83%
0.3% 83%
0.3% 83%
0.3% 86%
DC-DC 30W Triples
HD3-30-1A
9.0 12
25
3.21
V1 5.0
V2 +12
V3 - 12
V1 5.0
V2 +12
V3 - 12
V1 5.0
V2 +12
V3 - 12
V1 5.0
V2 +15
V3 - 15
V1 5.0
V2 +15
V3 - 15
V1 5.0
V2 +15
V3 - 15
6.00
0.50
0.50
6.00
0.50
0.50
6.00
0.50
0.50
6.00
0.40
0.40
6.00
0.40
0.40
6.00
0.40
0.40
1.0%
2.5%
2.5%
1.0%
2.5%
2.5%
1.0%
2.5%
2.5%
1.0%
2.5%
2.5%
1.0%
2.5%
2.5%
1.0%
2.5%
2.5%
0.3%
5.0% 78%
6.0%
0.3%
5.0% 81%
6.0%
0.3%
5.0% 82%
6.0%
0.3%
5.0% 78%
7.0%
0.3%
5.0% 81%
7.0%
0.3%
5.0% 82%
7.0%
HD3-30-1B
18
24
36
1.54
HD3-30-1D
36
48
75
0.76
HD3-30-2A
9.0 12
25
3.21
HD3-30-2B
18
24
36
1.54
HD3-30-2D
36
48
75
0.76
DC-DC 40W Singles
HD1-40-5A
HD1-40-5B
HD1-40-5D
HD1-40-12A
HD1-40-12B
HD1-40-12D
HD1-40-15A
HD1-40-15B
HD1-40-15D
鈥?/div>
9.0 12
18 24
36 48
9.0 12
18 24
36 48
9.0 12
18 24
36 48
25
36
75
25
36
75
25
36
75
4.20
2.03
1.00
4.12
2.01
1.00
4.02
2.01
0.97
V1 5.0
V1 5.0
V1 5.0
V1
V1
V1
V1
V1
V1
12
12
12
15
15
15
8.00
8.00
8.00
3.33
3.33
3.33
2.67
2.67
2.67
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
0.3% 79%
0.3% 82%
0.3% 83%
0.3% 81%
0.3% 83%
0.3% 83%
0.3% 83%
0.3% 83%
0.3% 86%
HD3-30 models with tightly regulated auxiliary outputs are available. For more
information, contact Power General applications engineering.
POWER
GENERAL
152 Will Drive 路 Canton, MA 02021 USA 路 Phone 781-828-6216 路 Fax 781-830-1155 路 Email power@nidecpg.com 路 http://www.nidec.com
47