Series H12
25-90Amp 鈥?480 Vac 鈥?AC Output
鈥?1200 Volt Blocking
鈥?Panel Mount
鈥?Up to 660 Vac
鈥?Zero Voltage Switching
and Random Turn-On
鈥?SCR Output
High voltage relays use IC driven cir-
cuits for switching loads up to 660
VAC. All models come with 1200
Volts blocking and are available with
either AC or DC input (coil) control.
Types H12CA, H12CD and H12WD are
snubberless (reduced leakage current).
Manufactured in Crydom鈥檚 ISO 9002
Certified facility for optimum product
performance and reliability.
MODEL NUMBERS
DC CONTROL
H12CD4850 H12CD4890
H12WD4850 H12WD4890
A C C ONTROL H12CA4850 H12CA4890
48-660
50
150
1200
625
1.6
.63
1620
1.0
500
48-660
90
150
1200
1200
1.6
.28
6000
1.0
500
H12D4825 H12D4850
H12D4875 H12D4890
OUTPUT SPECIFICATIONS
聦
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
聨
[Arms]
Min. Load Current, [mArms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (R
胃JC
) [藲C/W]
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/碌sec]
聧
Max. Turn-On Time
聫
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
48-530
25
150
1200
250
1.6
1.02
260
10
500
48-530
50
150
1200
625
1.6
.63
1620
10
500
48-530
75
150
1200
1000
1.6
.31
4150
10
500
48-530
90
150
1200
1200
1.6
.28
6000
10
500
1/2 Cycle (DC Control), 10.0 msec (AC Control)
1/2 Cycle (DC Control), 40.0 msec (AC Control)
0.5
0.5
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS
聦
(H12CD PREFIX)
DC CONTROL
(H12WD & H12D PREFIX)
AC CONTROL
(H12CA PREFIX)
Control Voltage Range
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current
4-8 Vdc
4.0 Vdc
1.0 Vdc
220 Ohms
15 mA @ 5 Vdc
4-32Vdc
4.0 Vdc
1.0 Vdc
See Note 5
15 mA @ 5 Vdc
聬
90-140 Vrms (60Hz)
90 Vrms
10.0 Vrms
8K Ohms
15 mA @ 120 Vrms
GENERAL NOTES
漏1998 CRYDOM CORP, Specifications subject to change without notice.
聦
All parameters at 25潞C unless otherwise specified.
聧
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
聨
Heat sinking required, for derating curves see page 2.
聫
Turn-on time for DC control random turn-on versions is 0.02 msec.
聬
Input circuitry incorporates active current limiter.
For recommended applications and more information contact:
USA:
(800) 8 CRYDOM
鈥?/div>
(800) 827-9366 鈥?(619) 715-7200 鈥?fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 鈥?e-mail: sales@crydom.com
WEB SITE:
http://www.crydom.com
FASTFAX Product Information:
(888) 267-9191
UK:
(44)1202 812300
鈥?/div>
fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY:
(49) (0)6874 182580
鈥?/div>
fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany 鈥?e-mail: vertrieb@crydom.com
FastFax Document No.157
SERIES H12.081898, PAGE 1 OF 3
next