Dual Relays
25-40Amp 鈥?120/240, 480 Vac 鈥?AC Output
鈥?Zero Voltage and Random
Turn-On Switching
鈥?SCR Output
鈥?Industry Standard Package
鈥?Panel Mount
Two totally independent AC output
relays come in a single standard panel-
mount package. Utilizing an AC switch
output with internal snubber, relays
provide greater protection against false
triggering. Model choices include zero-
voltage or random turn-on (phase con-
trollable) switching.
Manufactured in Crydom鈥檚 ISO 9002
Certified facility for optimum product
performance and reliability.
H12D4825D
H12D4840D
MODEL NUMBERS
D2425D
D2440D
OUTPUT SPECIFICATIONS
聦
Operating Voltage (47-63 Hz) [Vrms]
Load Current Range
聨
[Arms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (R
胃JC
) [藲C/W]
聦
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/碌sec]
聧
Max. Turn-On Time
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
24-280
.15-25
600
250
1.6
1.02
260
10
500
1/2 cycle
1/2 cycle
0.5
24-280
.15-40
600
625
1.6
.63
1620
10
500
1/2 cycle
1/2 cycle
0.5
48-530
.15-25
1200
250
1.6
1.02
260
10
500
1/2 cycle
1/2 cycle
0.5
48-530
.15-40
1200
625
1.6
.63
1620
10
500
1/2 cycle
1/2 cycle
0.5
聫
INPUT SPECIFICATIONS
聦
Control Voltage Range
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current @ 5Vdc
DC CONTROL
4-15Vdc
4.0 Vdc
1.0 Vdc
330 Ohms
12mA
漏1998 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
聦
All parameters at 25潞C and per section unless otherwise specified.
聧
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
聨
Heat sinking required, for derating curves see page 2.
聫
Turn-on time for random turn-on (-10) versions is 0.1 msec.
Crydom Heat Sinks
offer excellent thermal
management and are perfectly matched to the
load current ratings of Crydom panel mount
relays. Request Crydom鈥檚 Heat Sink specifica-
tion sheet for all the details.
FastFax Document No. 165
DUAL.032698, PAGE 1 OF 2
For recommended applications and more information contact:
USA:
(800) 8 CRYDOM
鈥?/div>
(800) 827-9366 鈥?(619) 715-7200 鈥?fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 鈥?e-mail: sales@crydom.com
WEB SITE:
http://www.crydom.com
FASTFAX Product Information:
(888) 267-9191
UK:
(44)1202 812300
鈥?/div>
fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY:
(49) (0)6874 182580
鈥?/div>
fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany 鈥?e-mail: vertrieb@crydom.com
next