GP2Y0A02YK
GP2Y0A02YK
I
Features
1. Less influence on the colors of reflected objects and their
reflectivity, due to optical triangle measuring method
2. Distance output type
(Detection range:20 to 150cm)
3. An external control circuit is not necessary
Output can be connected directly to a microcomputer
Long Distance Measuring
Sensor
I
Outline Dimensions
4-R1.75
#
#
(Unit : mm)
4-R1.75
Light detector
side
R3.75
13
11.9
+0.5
18.9
鈭?.3
37
29.5
4.475
19.8
鹵0.1
Lens case
R3.75
蠁3.2
Light emitter
side
蠁3.2
10.1
4.5
8.95
10.45
14.4
I
Applications
1. For detection of human body and various types of objects in
home appliances, OA equipment, etc
Connector
PWB
3.3
1.2
14.4
I
Absolute Maximum Ratings
Parameter
Supply voltage
*1
Output terminal voltage
Operating temperature
Storage temperature
*1 Open collector output
(T
a
=25擄C)
Symbol
Rating
Unit
V
鈭?.3
to
+7
V
CC
V
O
鈭?.3
to V
CC
+0.3
V
鈭?0
to
+60
T
opr
擄C
T
stg
鈭?0
to
+70
擄C
1 3
鉂?/div>
The dimensions marked are
described the dimensions of
lens center position.
鉂?/div>
Unspecified tolerance :
鹵0.3mm
#
2-1.5
21.6
Terminal connection
1
2
3
V
O
GND
V
CC
I
Recommended Operating Conditions
Parameter
Operating Supply voltage
Symbol
V
CC
Rating
4.5 to 5.5
Unit
V
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://sharp-world.com/ecg/
next